Frequency doubling technique in patients with ocular hypertension and glaucoma: correlation with octopus perimeter indices.

M Iester1, A Mermoud, C Schnyder.   

Abstract

PURPOSE: To ascertain whether frequency doubling technique (FDT) (Welch-Allyn, Skaneateles, NY; Zeiss-Humphrey, San Leandro, CA) indices provide results comparable with those of standard Octopus threshold perimeters (Interzeag AG, CH-8952 Schlieren, CH) in patients with glaucoma and in patients suspected of having ocular hypertension, glaucoma, or both.
DESIGN: A comparative, consecutive, case series. PARTICIPANTS: Thirty-nine glaucomatous patients and 41 patients with ocular hypertension or suspected glaucoma were recruited consecutively.
METHODS: The visual field of the study participants were assessed by FDT program C-20 full threshold and Octopus program dG1X. Only one eye of each participant was selected randomly. Pearson's r correlation coefficient was calculated among the FDT and Octopus indices. MAIN OUTCOME MEASURES: Using Octopus perimeter, mean defect (MD), mean sensitivity (MS), loss variance (LV), and corrected loss variance (CLV) were calculated and used for correlation. For the FDT, mean deviation (FDT-MD) and pattern standard deviation (FDT-PSD) were calculated and used for correlation. Also, the time required to perform the visual field test was considered.
RESULTS: In the entire population, a statistically significant correlation (Pearson's r, P<0.001) was found between FDT-MD and both MS (0.77) and MD (-0.80) and between FDT-PSD and both LV (0.50) and CLV (0.45). When the glaucoma group was considered alone, similar significant correlation was found between the indices. In the suspected ocular hypertension and glaucoma suspect group, no significant correlation was found. A significant (P<0.001) difference was found between FDT and Octopus for the time needed to perform the visual field test.
CONCLUSIONS: This new technique could be used both to screen populations and to observe glaucomatous visual field progression in early and moderate stages. The FDT is a faster way to analyze the visual field and captures threshold values for each point, but it is important to remember that this is a new technique and its limits are still unknown.

Entities:  

Mesh:

Year:  2000        PMID: 10690827     DOI: 10.1016/s0161-6420(99)00058-5

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  8 in total

1.  Relative hypersensitivity in healthy eye by frequency doubling perimetry in patients with severely damaged contralateral eye.

Authors:  N Fujimoto; D W Zhang; K Minowa; T Hanawa; O Miyauchi; E Adachi-Usami
Journal:  Br J Ophthalmol       Date:  2003-06       Impact factor: 4.638

2.  The distribution of visual field defects per quadrant in standard automated perimetry as compared to frequency doubling technology perimetry.

Authors:  Wadih M Zein; Ziad F Bashshur; Rola F Jaafar; Baha' N Noureddin
Journal:  Int Ophthalmol       Date:  2010-10-06       Impact factor: 2.031

3.  Comparative Analysis of Visual Field Plotting by Octopus Interzeag 1-2-3, Humphrey Field Analyser II and Frequency Doubling Perimetry in Glaucoma Patients in South Indian Population.

Authors:  A R Rajalakshmi; Elangovan Suma; D Ranjit Prabhu
Journal:  J Clin Diagn Res       Date:  2015-07-01

4.  Frequency doubling perimetry and the detection of eye disease in the community.

Authors:  G A Cioffi; S Mansberger; P Spry; C Johnson; E M Van Buskirk
Journal:  Trans Am Ophthalmol Soc       Date:  2000

5.  Possible association between heavy computer users and glaucomatous visual field abnormalities: a cross sectional study in Japanese workers.

Authors:  Masayuki Tatemichi; Tadashi Nakano; Katsutoshi Tanaka; Takeshi Hayashi; Takeshi Nawa; Toshiaki Miyamoto; Hisanori Hiro; Minoru Sugita
Journal:  J Epidemiol Community Health       Date:  2004-12       Impact factor: 3.710

6.  FDT Perimetry for Glaucoma Detection in Comprehensive Health Checkup Service.

Authors:  Ryo Terauchi; Takashi Wada; Shumpei Ogawa; Masanobu Kaji; Tomohiro Kato; Masayuki Tatemichi; Tadashi Nakano
Journal:  J Ophthalmol       Date:  2020-03-29       Impact factor: 1.909

7.  Risk Factors for Primary Open Angle Glaucoma (POAG) Progression: A Study Ruled in Torino.

Authors:  A G Actis; E Versino; B Brogliatti; T Rolle
Journal:  Open Ophthalmol J       Date:  2016-04-29

8.  Comparison of Matrix Frequency-Doubling Technology (FDT) Perimetry with the SWEDISH Interactive Thresholding Algorithm (SITA) Standard Automated Perimetry (SAP) in Mild Glaucoma.

Authors:  Azadeh Doozandeh; Farnoosh Irandoost; Ali Mirzajani; Shahin Yazdani; Mohammad Pakravan; Hamed Esfandiari
Journal:  Med Hypothesis Discov Innov Ophthalmol       Date:  2017
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.