Literature DB >> 10688116

Performance of a 62Zn/62Cu generator in clinical trials of PET perfusion agent 62Cu-PTSM.

N G Haynes1, J L Lacy, N Nayak, C S Martin, D Dai, C J Mathias, M A Green.   

Abstract

UNLABELLED: The 62Zn/62Cu PET generator can be inexpensively produced and distributed from a single production site operating under typical good manufacturing practice guidelines. It therefore has the potential to greatly facilitate development of clinically practical PET. We report generator performance in a study in which 62Cu-pyruvaldehyde-bis(n4-methylthiosemicarbazone (PTSM) myocardial perfusion imaging is compared with 99mTc-sestamibi in the diagnosis of coronary artery disease. The 62Zn/62Cu generator is an improved version of a previously reported system that employs automated synthesis of 62Cu-PTSM. With this approach, the cumbersome step of 18C purification has been eliminated.
METHODS: The 62Zn (9.3 h half-life) parent isotope is prepared by proton bombardment of natural copper at 33 MeV. A typical target irradiated with 37.5 microA/h is delivered by 12:00 PM on the day it is to be processed. Purified 62Zn obtained from the target is loaded onto the generator column in 2 mol/L HCl. The generator is eluted using an internal three-channel peristaltic pump, which delivers 2.25 mL eluant (1.8 mol/L NaCl, 0.2 mol/L HCl) through the generator column to elute the 62Cu in 40 s. The same pump simultaneously pumps an equal volume of buffer (0.4 mol/L NaOAc) and 1 mL ligand solution (2 ppm PTSM, 2% EtOH) passing it through a septum into a 35-cc syringe preloaded with 28 mL sterile water. This solution is thoroughly mixed by agitation of the syringe and injected as a bolus through a 0.2 microm filter. The generator is eluted twice before shipping, providing quality assurance samples, and shipped to the clinical site by overnight delivery. Complete quality assurance testing is performed the evening before the generator reaches the clinical site.
RESULTS: A total of 34 generators have been produced and shipped to 2 clinical sites for a phase III Food and Drug Administration study. The load activity on the generators at 8:00 AM the day of clinical use was 1.7+/-0.2 GBq (46.7+/-5.6 mCi), and yield was 72%+/-16%. Breakthrough of 62Zn was undetectable by high-purity germanium spectroscopy for all units. Radiochemical purity was 95.4%+/-2.4%. Volume delivered, pH, sterility, and bacterial endotoxin tests yielded passing results on all generators. The entire process of generator production, from target receipt to generator shipment, took less than 6 h and cost approximately $1000, including shipping charges and cyclotron cost. A total of 68 patients were injected with 2 62Cu-PTSM doses, with a mean injected activity of 0.8+/-0.2 GBq (20.5+/-5.3 mCi) with no adverse side effects.
CONCLUSION: Results of this work confirm that the 62Zn/62Cu generator is an easily produced, transportable, and inexpensive source of PET radiopharmaceuticals, which can expand the field of clinical PET imaging by providing radiopharmaceuticals to sites not associated with cyclotrons.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10688116

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  18 in total

Review 1.  Coordinating radiometals of copper, gallium, indium, yttrium, and zirconium for PET and SPECT imaging of disease.

Authors:  Thaddeus J Wadas; Edward H Wong; Gary R Weisman; Carolyn J Anderson
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

Review 2.  Bifunctional coupling agents for radiolabeling of biomolecules and target-specific delivery of metallic radionuclides.

Authors:  Shuang Liu
Journal:  Adv Drug Deliv Rev       Date:  2008-04-23       Impact factor: 15.470

3.  Towards new horizons in brain PET.

Authors:  Marco Pagani
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-06       Impact factor: 9.236

4.  A practical guide to the construction of radiometallated bioconjugates for positron emission tomography.

Authors:  Brian M Zeglis; Jason S Lewis
Journal:  Dalton Trans       Date:  2011-03-25       Impact factor: 4.390

5.  A comparison of PET imaging characteristics of various copper radioisotopes.

Authors:  Heather Ann Williams; Simon Robinson; Peter Julyan; Jamal Zweit; David Hastings
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-10-29       Impact factor: 9.236

Review 6.  Production of radiometals in liquid targets.

Authors:  Sergio J C do Carmo; Peter J H Scott; Francisco Alves
Journal:  EJNMMI Radiopharm Chem       Date:  2020-01-10

7.  Dosimetry of 60/61/62/64Cu-ATSM: a hypoxia imaging agent for PET.

Authors:  Richard Laforest; Farrokh Dehdashti; Jason S Lewis; Sally W Schwarz
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-03-23       Impact factor: 9.236

Review 8.  Radiolabeled cyclic RGD peptides as integrin alpha(v)beta(3)-targeted radiotracers: maximizing binding affinity via bivalency.

Authors:  Shuang Liu
Journal:  Bioconjug Chem       Date:  2009-12       Impact factor: 4.774

9.  PET of hypoxia and perfusion with 62Cu-ATSM and 62Cu-PTSM using a 62Zn/62Cu generator.

Authors:  Terence Z Wong; Jeffrey L Lacy; Neil A Petry; Thomas C Hawk; Thomas A Sporn; Mark W Dewhirst; Gordana Vlahovic
Journal:  AJR Am J Roentgenol       Date:  2008-02       Impact factor: 3.959

10.  In vivo assessment of tumor hypoxia in lung cancer with 60Cu-ATSM.

Authors:  Farrokh Dehdashti; Mark A Mintun; Jason S Lewis; Jeffrey Bradley; Ramaswamy Govindan; Richard Laforest; Michael J Welch; Barry A Siegel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-04-12       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.