Literature DB >> 10686058

Performance characteristics of the AmpliScreen HIV-1 test, an assay designed for screening plasma mini-pools.

Y Yang1, M H Wisbeski, M Mendoza, S Dorf, D Xu, M Nguyen, S Yeh, R Sun.   

Abstract

This study evaluated the performance characteristics of the AmpliScreen(TM)Human Immunodeficiency Virus-Type 1 (HIV-1) Test, Version 1.5, a test designed for screening pools composed of samples from individual units of blood or plasma. HIV-1, hepatitis C (HCV) and hepatitis B (HBV) virus particles were simultaneously extracted and concentrated from plasma by a multi-prep sample processing procedure. An HIV-1 Internal Control (IC) RNA was added to each sample to serve as an extraction and amplification control. Processed samples were amplified by RT-PCR using HIV-1-specific complementary primers and detected by hybridization of the amplified products to HIV-1- and IC-specific oligonucleotide probes. The analytical sensitivity of the test (concentration that yields >/=95% positive results in a set of replicate tests) was 25 copies of HIV-1 RNA per mL of pooled plasma. Representative strains from all HIV-1 group M subtypes were reproducibly detected (>95% positive results among 22 replicate tests) at concentrations of 30 to 75 viral particles per ml. The test exhibited excellent specificity; it did not cross-react with a set of 30 viral and five bacterial isolates and yielded negative results on a panel of 500 blood samples from HIV-1 seronegative donors. Samples containing abnormally high levels of haemoglobin, albumin, triglycerides or bilirubin in plasma samples did not interfere with the detection of HIV-1 RNA at a concentration of 100 copies of per ml. The test detected HIV-1 RNA 7-17 days prior to anti-HIV-1 antibody seroconversion for all 10 seroconversion panels tested. A fully automated COBAS AmpliScreen(TM)version of this test is being validated. COBAS AmpliScreen tests for HCV and HBV also incorporate the multi-prep specimen processing method, thereby making it possible to use a single processed specimen to screen for all three viruses.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10686058     DOI: 10.1006/biol.1999.0226

Source DB:  PubMed          Journal:  Biologicals        ISSN: 1045-1056            Impact factor:   1.856


  2 in total

1.  PHS guideline for reducing human immunodeficiency virus, hepatitis B virus, and hepatitis C virus transmission through organ transplantation.

Authors:  Debbie L Seem; Ingi Lee; Craig A Umscheid; Matthew J Kuehnert
Journal:  Public Health Rep       Date:  2013-07       Impact factor: 2.792

2.  False-positive results with select HIV-1 NAT methods following lentivirus-based tisagenlecleucel therapy.

Authors:  Theodore W Laetsch; Shannon L Maude; Michael C Milone; Kara L Davis; Joerg Krueger; Ana Maria Cardenas; Lamis K Eldjerou; Christopher H Keir; Patricia A Wood; Stephan A Grupp
Journal:  Blood       Date:  2018-04-18       Impact factor: 22.113

  2 in total