Literature DB >> 10685691

Doppler ultrasonographic features of thoracic limb arteries in clinically normal horses.

T Cochard1, R L Toal, A M Saxton.   

Abstract

OBJECTIVES: To determine blood flow velocities and indices from spectral waveforms obtained by use of Doppler ultrasonography of thoracic limb arteries of horses and to assess interobserver and patient variability associated with the technique. ANIMALS: 9 clinically normal adult horses. PROCEDURE: Left thoracic limb arteries of 8 nonsedated horses were examined at 5 sites by use of pulsed-wave Doppler ultrasonography to determine a range of values for peak systolic, end diastolic, and mean velocities and resistive and pulsatility indices. Interobserver and patient variabilities were determined by 2 operators repeating similar measurements on 1 horse 8 times at weekly intervals.
RESULTS: A range of values for each variable measured at the 5 selected sites was obtained. For each variable, strong positive correlations (R > or = 0.7) were detected for > 70% of the site-to-site comparisons made (excluding the coronary band). Among horses, resistive index varied least, whereas over time, mean velocity varied least. Waveform characteristics were consistent with resistive (n = 5) or nonresistive (4) patterns. In the single-horse experiment, waveform characteristics were consistent throughout the 8 weeks, and operator effects were not detected. CONCLUSIONS AND CLINICAL RELEVANCE: Doppler ultrasonography of no one site resulted in more reliable measurements of blood flow characteristics in thoracic limb arteries of horses. Mean velocity and resistive index were the least variable measurements made. Pulsed-wave Doppler ultrasonography may be a useful technique for evaluating diseases that alter normal thoracic limb arterial blood flow in horses.

Entities:  

Mesh:

Year:  2000        PMID: 10685691     DOI: 10.2460/ajvr.2000.61.183

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  2 in total

1.  Evaluation of arterial digital blood flow using Doppler ultrasonography in healthy dairy cows.

Authors:  H Müller; M Heinrich; N Mielenz; S Reese; A Steiner; A Starke
Journal:  BMC Vet Res       Date:  2017-06-06       Impact factor: 2.741

2.  Pulse wave Doppler ultrasound of testicular arteries and their relationship with semen characteristics in healthy bulls.

Authors:  Alessia Gloria; Augusto Carluccio; Laura Wegher; Domenico Robbe; Claudio Valorz; Alberto Contri
Journal:  J Anim Sci Biotechnol       Date:  2018-02-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.