Literature DB >> 10685241

Comparison of DNA probe technology and automated continuous-monitoring blood culture systems in the detection of neonatal bacteremia.

D Hertz1, D Fuller, T Davis, L Papile, D Stevenson, J Lemons.   

Abstract

OBJECTIVE: The present study assessed the ability of a rapid chemiluminescent DNA probe assay to detect bacterial growth in blood culture specimens before their detection by continuous-monitoring blood culture (CMBC) systems. STUDY
DESIGN: Three newborn intensive care units, which are members of the National Institute of Child Health and Human Development Neonatal Research Network, participated in this study. Each center employs an automated CMBC system against which the DNA probe was compared. A total of 1700 blood cultures were analyzed. A 3-ml aliquot of culture medium was removed from each culture during early incubation, processed, and analyzed by the DNA probe.
RESULTS: Of 1700 blood cultures, 130 (7.6%) were detected positive by a CMBC system. Coagulase-negative staphylococci (CNS) were present in 90 (69%) of the positive cultures, and 26 (29%) were detected by the DNA probe. Other organisms accounted for the remaining 40 positive cultures, and 31 (78%) of these were detected by the probe assay. Seventy-six percent of all positive cultures were detected by a CMBC system within 24 hours. Ninety-eight percent of all positive cultures were detected by a CMBC system within 48 hours. Of the two organisms that grew in a CMBC system beyond 48 hours, both were CNS and one of these was considered a contaminant. Therefore, 99% of clinically significant organisms were detected by a CMBC system within 48 hours.
CONCLUSION: This DNA probe is not sufficiently sensitive to be clinically useful; however, automated CMBC systems are sufficiently sensitive to aid in clinical decision-making regarding the continuance or discontinuance of antibiotic therapy following 48 hours of culture incubation.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10685241     DOI: 10.1038/sj.jp.7200156

Source DB:  PubMed          Journal:  J Perinatol        ISSN: 0743-8346            Impact factor:   2.521


  3 in total

1.  Conventional and molecular methods for verification of results obtained with BacT/Alert Nonvent blood culture bottles.

Authors:  Elizabeth M Marlowe; Linda Gibson; James Hogan; Shannon Kaplan; David A Bruckner
Journal:  J Clin Microbiol       Date:  2003-03       Impact factor: 5.948

2.  Application of an rRNA probe matrix for rapid identification of bacteria and fungi from routine blood cultures.

Authors:  Elizabeth M Marlowe; James J Hogan; Janet F Hindler; Irene Andruszkiewicz; Pat Gordon; David A Bruckner
Journal:  J Clin Microbiol       Date:  2003-11       Impact factor: 5.948

3.  Significance of Hematological Scoring System (HSS) in Early Diagnosis of Neonatal Sepsis.

Authors:  Aparna Narasimha; M L Harendra Kumar
Journal:  Indian J Hematol Blood Transfus       Date:  2011-01-01       Impact factor: 0.900