Literature DB >> 1068505

Influence of maturation status and tooth type of permanent teeth upon electrometric and thermal pulp testing.

H J Fulling, J O Andreasen.   

Abstract

The threshold values of developing teeth were determined for two commonly used electrometric pulp testers (Siemens Sirotest and Bofors Pulp Tester) and a new thermal test based on carbon dioxide snow (Odontotest). The teeth examined were divided into 7 stages according to maturation status. This study showed that teeth in Stages 3-5, i.e. until completion of root formation, show an increased electrometric threshold value. The Siemens tester appeared to be equal to the Bofors tester with regard to reliability. The Odontotest was the most reliable method examined, giving a consistent positive response in all examined teeth.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 1068505     DOI: 10.1111/j.1600-0722.1976.tb00491.x

Source DB:  PubMed          Journal:  Scand J Dent Res        ISSN: 0029-845X


  8 in total

1.  Pulp blood flow and sensibility in patients with a history of dental trauma undergoing maxillary expansion.

Authors:  Raymond Lam; Mithran S Goonewardene; Steven Naoum
Journal:  Angle Orthod       Date:  2020-09-01       Impact factor: 2.079

2.  [Disorders of the sensitivity of the anterior teeth in children and adolescents].

Authors:  U Billen; C W Schwarze; D van Laere
Journal:  Fortschr Kieferorthop       Date:  1989-10

3.  Fiber-based laser speckle imaging for the detection of pulsatile flow.

Authors:  Caitlin Regan; Bruce Y Yang; Kent C Mayzel; Julio C Ramirez-San-Juan; Petra Wilder-Smith; Bernard Choi
Journal:  Lasers Surg Med       Date:  2015-08       Impact factor: 4.025

4.  Pulp sensibility tests responses in patients with anxiety and depression.

Authors:  Narges Farhad-Mollashahi; Mahboubeh-Firouzkouhi Moghadam; Seyed-Mohammad-Javad Aslani; Forugh Mollashahi
Journal:  J Clin Exp Dent       Date:  2022-05-01

5.  Dental pulp testing: a review.

Authors:  Eugene Chen; Paul V Abbott
Journal:  Int J Dent       Date:  2009-11-12

6.  Pulp sensitivity changes during orthodontic treatment at different time periods: a prospective study.

Authors:  Benjamín Briseño-Marroquín; Héctor López-Murillo; Robert Kuchen; Adán Casasa-Araujo; Thomas Gerhard Wolf
Journal:  Clin Oral Investig       Date:  2020-12-07       Impact factor: 3.573

7.  Reliability of Electric Pulp Test, Cold Pulp Test or Tooth Transillumination to Assess Pulpal Health in Permanent Dog Teeth.

Authors:  Caroline Proulx; Yvan Dumais; Guy Beauchamp; Paulo Steagall
Journal:  J Vet Dent       Date:  2022-03-08       Impact factor: 1.154

8.  Relationship between the difference in electric pulp test values and the diagnostic type of pulpitis.

Authors:  Huachao Sui; Yangyang Lv; Mo Xiao; Liwen Zhou; Feng Qiao; Jinxin Zheng; Cuicui Sun; Jieni Fu; Yufan Chen; Yimeng Liu; Jie Zhou; Ligeng Wu
Journal:  BMC Oral Health       Date:  2021-07-10       Impact factor: 2.757

  8 in total