Literature DB >> 10683783

Closed chamber iridodialysis repair using a needle with a distal hole.

Y Bardak1, Y Ozerturk, M Durmus, E Mensiz, E Aytuluner.   

Abstract

We describe a closed-system technique of iridodialysis repair using a 22.0 mm, plastic handled, 27 gauge straight needle with a hole 1.0 mm proximal to the tip. The distal hole is suitable for passage of 9-0 or 10-0 mm polypropylene or nylon sutures. The technique was effective in 8 patients with traumatic iridodialysis in the upper and inferior temporal quadrants.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10683783     DOI: 10.1016/s0886-3350(99)00365-x

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  8 in total

1.  Iridodialysis repair: stroke and dock technique.

Authors:  Sudarshan Khokhar; Shikha Gupta; Gaurav Kumar
Journal:  Int Ophthalmol       Date:  2013-05-03       Impact factor: 2.031

2.  Suturing repair of subtotal iridodialysis.

Authors:  Yoko Okamoto; Shogo Yamada; Masayuki Akimoto
Journal:  Int Ophthalmol       Date:  2017-02-07       Impact factor: 2.031

3.  Flapless and transconjunctival double knot technique to repair iridodialysis.

Authors:  Xin Hu; Bo Zhao; Hai-Ying Jin
Journal:  Int J Ophthalmol       Date:  2022-03-18       Impact factor: 1.779

4.  Results of a novel surgical technique for iridodialysis repair using an iris retractor segment.

Authors:  Ugur Unsal; Huri Sabur; Mehmet Soyler
Journal:  Int Ophthalmol       Date:  2021-08-22       Impact factor: 2.031

5.  Single suture customized loop for large iridodialysis repair.

Authors:  Mohamed Omar Yousif
Journal:  Clin Ophthalmol       Date:  2016-09-28

6.  Comparing safety and efficiency of two closed-chamber techniques for iridodialysis repair - a retrospective clinical study.

Authors:  Wenjuan Wan; Lei Shi; Can Li
Journal:  BMC Ophthalmol       Date:  2018-12-07       Impact factor: 2.209

7.  Iris and knot configuration after Single Pass Four Throw (SFT) pupilloplasty as imaged by the spectral-domain optical coherence tomography.

Authors:  Dhivya Ashok Kumar; Amar Agarwal; Radhika Chandrasekar; Nagaraj Jaganathasamy
Journal:  Indian J Ophthalmol       Date:  2019-02       Impact factor: 1.848

8.  Cobbler's Technique for Iridodialysis Repair.

Authors:  Surinder Singh Pandav; Parul Chawla Gupta; Rishi Raj Singh; Kalpita Das; Sushmita Kaushik; Srishti Raj; Jagat Ram
Journal:  Middle East Afr J Ophthalmol       Date:  2016 Jan-Mar
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.