Literature DB >> 10682776

MR angiography of the thoracic aorta with an electrocardiographically triggered breath-hold contrast-enhanced sequence.

P J Arpasi1, K G Bis, A N Shetty, R D White, O P Simonetti.   

Abstract

An electrocardiographically (ECG) triggered breath-hold contrast material-enhanced magnetic resonance (MR) angiography sequence has been developed for imaging the thoracic aorta. A three-dimensional (3D) gradient-echo sequence is used with a contrast material bolus. Forty-nine patients with various aortic abnormalities and five healthy volunteers underwent imaging with the sequence. All studies were performed in a single breath hold. ECG-triggered breath-hold contrast-enhanced MR angiography was tolerated in 48 of the 49 patients. The images demonstrated no respiratory motion artifacts and diminished pulsation artifacts. The cardiac chambers, aortic root, ascending and descending aorta, aortic arch, proximal arch vessels, and proximal coronary arteries were clearly demonstrated and not obscured by ghost artifacts. The 3D data set allowed excellent multiplanar reformation, permitting orthogonal or oblique views of the vascular anatomy. A variety of congenital and acquired abnormalities were clearly identified. When this sequence is used, it is important to evaluate both the maximum-intensity projection and source images. Delayed imaging should be performed to detect late filling. In conjunction with cine MR and T1-weighted spin-echo imaging, ECG-triggered breath-hold contrast-enhanced MR angiography should be considered the technique of choice for imaging the thoracic aorta.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10682776     DOI: 10.1148/radiographics.20.1.g00ja24107

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  6 in total

Review 1.  Review of new techniques in echocardiography and magnetic resonance imaging as applied to patients with congenital heart disease.

Authors:  D J Sahn; G W Vick
Journal:  Heart       Date:  2001-12       Impact factor: 5.994

2.  Non-gadolinium-enhanced 3-dimensional magnetic resonance angiography for the evaluation of thoracic aortic disease: a preliminary experience.

Authors:  Monvadi B Srichai; Sooah Kim; Leon Axel; James Babb; Elizabeth M Hecht
Journal:  Tex Heart Inst J       Date:  2010

3.  MRI assessment of thoracic stent grafts after emergency implantation in multi trauma patients: a feasibility study.

Authors:  Volker Rasche; Alexander Oberhuber; Stephan Trumpp; Axel Bornstedt; Karl-Heinz Orend; Nico Merkle; Wolfgang Rottbauer; Martin Hoffmann
Journal:  Eur Radiol       Date:  2011-02-18       Impact factor: 5.315

Review 4.  Coronary computed tomographic angiography (CCTA) in community hospitals: "current and emerging role".

Authors:  Rakesh K Sharma; Donald J Voelker; Rajiv K Sharma; Vibhuti N Singh; Girish Bhatt; Mathilde Moazazi; Teresa Nash; Hanumanth K Reddy
Journal:  Vasc Health Risk Manag       Date:  2010-05-25

5.  ACR Appropriateness Criteria(®) blunt chest trauma--suspected aortic injury.

Authors:  Shadpour Demehri; Frank J Rybicki; Benoit Desjardins; Chieh-Min Fan; Scott D Flamm; Christopher J Francois; Marie D Gerhard-Herman; Sanjeeva P Kalva; Hyun S Kim; M Ashraf Mansour; Emile R Mohler; Isabel B Oliva; Matthew P Schenker; Clifford Weiss; Karin E Dill
Journal:  Emerg Radiol       Date:  2012-03-18

6.  4D MUSIC CMR: value-based imaging of neonates and infants with congenital heart disease.

Authors:  Kim-Lien Nguyen; Fei Han; Ziwu Zhou; Daniel Z Brunengraber; Ihab Ayad; Daniel S Levi; Gary M Satou; Brian L Reemtsen; Peng Hu; J Paul Finn
Journal:  J Cardiovasc Magn Reson       Date:  2017-04-03       Impact factor: 5.364

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.