Literature DB >> 10680694

Demonstration of a compact compressor for application of metastability-exchange optical pumping of 3He to human lung imaging.

T R Gentile1, G L Jones, A K Thompson, R R Rizi, D A Roberts, I E Dimitrov, R Reddy, D A Lipson, W Gefter, M D Schnall, J S Leigh.   

Abstract

Hyperpolarized gas magnetic resonance imaging has recently emerged as a method to image lungs, sinuses, and the brain. The best lung images to date have been produced using hyperpolarized 3He, which is produced by either spin-exchange or metastability-exchange optical pumping. For hyperpolarized gas MRI, the metastable method has demonstrated higher polarization levels and higher polarizing rates, but it requires compression of the hyperpolarized gas. Prior to this work, compression of hyperpolarized gas had only been accomplished using a large, complex and expensive apparatus. Here, human lung ventilation images are presented that were obtained using a compact compressor that is relatively simple and inexpensive. For this test, 1.1 bar-L of 15% hyperpolarized 3He gas was produced at the National Institute of Standards and Technology using a modified commercial diaphragm pump. The hyperpolarized gas was transported to the University of Pennsylvania in a holding field provided by a portable solenoid.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10680694     DOI: 10.1002/(sici)1522-2594(200002)43:2<290::aid-mrm17>3.0.co;2-a

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

Review 1.  Lung imaging in asthmatic patients: the picture is clearer.

Authors:  Mario Castro; Sean B Fain; Eric A Hoffman; David S Gierada; Serpil C Erzurum; Sally Wenzel
Journal:  J Allergy Clin Immunol       Date:  2011-06-02       Impact factor: 10.793

2.  A new direction for polarized carbon-13 MRI.

Authors:  Rahim R Rizi
Journal:  Proc Natl Acad Sci U S A       Date:  2009-03-31       Impact factor: 11.205

Review 3.  3He diffusion MRI in human lungs.

Authors:  Jason C Woods; Mark S Conradi
Journal:  J Magn Reson       Date:  2018-04-26       Impact factor: 2.229

4.  Pulmonary MRI contrast using Surface Quadrupolar Relaxation (SQUARE) of hyperpolarized (83)Kr.

Authors:  Joseph S Six; Theodore Hughes-Riley; David M L Lilburn; Alan C Dorkes; Karl F Stupic; Dominick E Shaw; Peter G Morris; Ian P Hall; Galina E Pavlovskaya; Thomas Meersmann
Journal:  Magn Reson Imaging       Date:  2013-10-18       Impact factor: 2.546

5.  Cryogenics free production of hyperpolarized 129Xe and 83Kr for biomedical MRI applications.

Authors:  Theodore Hughes-Riley; Joseph S Six; David M L Lilburn; Karl F Stupic; Alan C Dorkes; Dominick E Shaw; Galina E Pavlovskaya; Thomas Meersmann
Journal:  J Magn Reson       Date:  2013-09-21       Impact factor: 2.229

6.  Compressing Spin-Polarized (3)He With a Modified Diaphragm Pump.

Authors:  T R Gentile; D R Rich; A K Thompson; W M Snow; G L Jones
Journal:  J Res Natl Inst Stand Technol       Date:  2001-08-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.