Literature DB >> 10680359

Modeling relationships between indoor and outdoor air quality.

J I Freijer1, H J Bloemen.   

Abstract

Information about the ratio between indoor and outdoor concentrations (IO ratios) of air pollutants is a crucial component in human exposure assessment. The present study examines the relationship between indoor and outdoor concentrations as influenced by the combined effect of time patterns in outdoor concentrations, ventilation rate, and indoor emissions. Two different mathematical approaches are used to evaluate IO ratios. The first approach involves a dynamic mass balance model that calculates distributions of transient IO ratios. The second approach assumes a linear relationship between indoor and outdoor concentrations. We use ozone and benzene as examples in various modeling exercises. The modeled IO ratio distributions are compared with the results obtained from linear fits through plots of indoor versus outdoor concentrations.

Entities:  

Mesh:

Year:  2000        PMID: 10680359     DOI: 10.1080/10473289.2000.10464007

Source DB:  PubMed          Journal:  J Air Waste Manag Assoc        ISSN: 1096-2247            Impact factor:   2.235


  6 in total

1.  Temporal evolution of the main processes that control indoor pollution in an office microenvironment: a case study.

Authors:  Christos H Halios; Costas G Helmis
Journal:  Environ Monit Assess       Date:  2009-06-27       Impact factor: 2.513

2.  Migration of contaminated soil and airborne particulates to indoor dust.

Authors:  David W Layton; Paloma I Beamer
Journal:  Environ Sci Technol       Date:  2009-11-01       Impact factor: 9.028

3.  Inflammatory responses to acute elevations of carbon dioxide in mice.

Authors:  Stephen R Thom; Veena M Bhopale; JingPing Hu; Ming Yang
Journal:  J Appl Physiol (1985)       Date:  2017-05-11

4.  Building-Related Symptoms among Office Employees Associated with Indoor Carbon Dioxide and Total Volatile Organic Compounds.

Authors:  Chung-Yen Lu; Jia-Min Lin; Ying-Yi Chen; Yi-Chun Chen
Journal:  Int J Environ Res Public Health       Date:  2015-05-27       Impact factor: 3.390

5.  Personal, Psychosocial and Environmental Factors Related to Sick Building Syndrome in Official Employees of Taiwan.

Authors:  Chung-Yen Lu; Meng-Chuan Tsai; Chih-Hsin Muo; Yu-Hsien Kuo; Fung-Chang Sung; Chin-Ching Wu
Journal:  Int J Environ Res Public Health       Date:  2017-12-22       Impact factor: 3.390

6.  Influence of mechanical ventilation system on indoor carbon dioxide and particulate matter concentration.

Authors:  Conson K H Yu; Min Li; Vincent Chan; Alvin C K Lai
Journal:  Build Environ       Date:  2014-03-13       Impact factor: 6.456

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.