Literature DB >> 10679685

High-resolution electron microscopy study of synthetic carbonate and aluminum containing apatites.

J D Layani1, F J Cuisinier, P Steuer, H Cohen, J C Voegel, I Mayer.   

Abstract

Aluminum (Al)-containing calcium-deficient carbonated hydroxyapatites were produced by a precipitation method from aqueous solution with carbonate (0-6.1%) and aluminum (0.1-0.5%) concentrations close to those found in biological materials. Two series of apatites were prepared: one at pH 7.0 and another at pH 9. 0. High-resolution electron microscopy has shown that many of them possess structural defects such as screw dislocations, grain boundaries, and central defects. Samples with high carbonate content and high water and high Al(3+) content had a high amount of structural defects. Accordingly, a sample (7Al1) with a relatively high carbonate content (6.1%) and a sample (7Al6) without carbonate but with a relatively high water (2.0 mol) and Al(3+) content (0. 39%) presented the highest amount of structural defects, 54% and 47%, respectively. A sample (7Al13) with a low level of crystalline water (1 mol) and low carbonate (2.5%) showed a small amount of defects. The presence of water associated with Al(3+) induced a high number of crystals having a central defect with a great similarity to the so-called water layer of octacalcium phosphate (OCP). Observed images of all these crystals have shown good correspondence with the computer-simulated image based on the crystal structure of hydroxyapatite, indicating that the addition of Al(3+) and carbonate does not perturb the apatitic structure. Copyright 2000 John Wiley & Sons, Inc.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10679685     DOI: 10.1002/(sici)1097-4636(200005)50:2<199::aid-jbm15>3.0.co;2-q

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  4 in total

1.  Ultrastructural analyses of nanoscale apatite biomimetically grown on organic template.

Authors:  S I Hong; K H Lee; M E Outslay; D H Kohn
Journal:  J Mater Res       Date:  2008-02-01       Impact factor: 3.089

2.  Effect of carbonate substitution on the ultrastructural characteristics of hydroxyapatite implants.

Authors:  A Porter; N Patel; R Brooks; S Best; N Rushton; W Bonfield
Journal:  J Mater Sci Mater Med       Date:  2005-10       Impact factor: 3.896

3.  In vivo assessment of hydroxyapatite and silicate-substituted hydroxyapatite granules using an ovine defect model.

Authors:  N Patel; R A Brooks; M T Clarke; P M T Lee; N Rushton; I R Gibson; S M Best; W Bonfield
Journal:  J Mater Sci Mater Med       Date:  2005-05       Impact factor: 3.896

4.  Empirical and theoretical insights into the structural effects of selenite doping in hydroxyapatite and the ensuing inhibition of osteoclasts.

Authors:  Victoria M Wu; M K Ahmed; Mervat S Mostafa; Vuk Uskoković
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2020-07-06       Impact factor: 7.328

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.