Literature DB >> 10673118

Modeling the stability of the human glenohumeral joint during external rotation.

J E Novotny1, B D Beynnon, C E Nichols.   

Abstract

An analytical model of the human glenohumeral joint was developed to predict glenohumeral kinematics and investigate how the glenohumeral capsule and articular contact between the humeral head and the glenoid stabilize the joint. This was performed during a simulation of an apprehension clinical exam or the cocked phase of throwing, when the humerus is susceptible to anterior instability or dislocation. Contact between the joint surfaces was modeled using a deformable articular contact method and the capsule was modeled as five elements with the ability to wrap around the surface of the humeral head. Experimental measurements (Novotny et al., Journal of Shoulder and Elbow surgery, 1998, 7, 629-639) provided geometric data from four in vitro specimens and kinematic results to validate model predictions. Material properties were taken from the literature. An equilibrium approach was used with the forces and moments produced by the ligaments and surface contact balanced against those applied externally to the humerus during external rotation of the abducted and extended humerus. The six equilibrium equations were solved for the position and orientation of the humerus. The center of the humeral head translated posteriorly and superiorly with external rotation. Model predictions for translational and rotational ranges of motion were not significantly different from experimental findings; however, at individual moment increments, the model underestimated the external rotation and overestimated the superior-inferior position of the humerus relative to the glenoid. The anterior band of the inferior glenohumeral ligament increased in tension with external rotation, while the axillary pouch and posterior band decreased in tension. Contact area, stress and force increased with external rotation and the contact area moved posteriorly and inferiorly around the rim of the glenoid. The model results provide information on how the relationship between the ligament element tensions and contact forces may act to avoid glenohumeral instability.

Entities:  

Mesh:

Year:  2000        PMID: 10673118     DOI: 10.1016/s0021-9290(99)00142-6

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  6 in total

1.  Definition of the capsular insertion plane on the proximal humerus.

Authors:  Hippolite O Amadi; Sanjay M Sanghavi; Srinath Kamineni; Roman Skourat; Ulrich N Hansen; Anthony M J Bull
Journal:  J Anat       Date:  2008-04-21       Impact factor: 2.610

2.  A finite element model of the shoulder: application to the changes of biomechanical environment induced by postoperative malrotation of humeral shaft fracture.

Authors:  Cheng Wang; Xiao-Yuan Ma; Lin-Tao Lu; Zheng Guo; Guo-Feng Dai
Journal:  BMC Musculoskelet Disord       Date:  2022-06-02       Impact factor: 2.562

3.  An optimised method for quantifying glenoid orientation.

Authors:  Hippolite O Amadi; Sughran Banerjee; Ulrich N Hansen; Andrew L Wallace; Anthony M J Bull
Journal:  Int J Shoulder Surg       Date:  2008-04

4.  The glenohumeral capsule should be evaluated as a sheet of fibrous tissue: a validated finite element model.

Authors:  Susan M Moore; Benjamin Ellis; Jeffrey A Weiss; Patrick J McMahon; Richard E Debski
Journal:  Ann Biomed Eng       Date:  2009-11-13       Impact factor: 3.934

5.  A biomechanical assessment of superior shoulder translation after reconstruction of anterior glenoid bone defects: The Latarjet procedure versus allograft reconstruction.

Authors:  Ryan M Degen; Joshua W Giles; Harm W Boons; Robert B Litchfield; James A Johnson; George S Athwal
Journal:  Int J Shoulder Surg       Date:  2013-01

6.  A survey of human shoulder functional kinematic representations.

Authors:  Rakesh Krishnan; Niclas Björsell; Elena M Gutierrez-Farewik; Christian Smith
Journal:  Med Biol Eng Comput       Date:  2018-10-26       Impact factor: 2.602

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.