Literature DB >> 10672602

[Sonographic imaging of leg geometry].

P Keppler1, W Strecker, L Kinzl, M Simmnacher, L Claes.   

Abstract

Posttraumatic malalignments are a frequent sequlae of IM nailing of lower extremity fractures. Conventional US has proven to be inferior to CT determinations of tibial or femural length and torsion. A new 3-D US method is presented that allows for accurate single step determination of lower extremity length and torsion without ionizing radiation. A regular US machine with a 5 Mhz linear probe is combined with an US localizer. Reference markers affixed to the lower extremity eliminate errors associated with patient position or motion. The 3-D US method was compared against CT (Ulm's method) in the measurement of torsion and length of the tibia and femur in 50 adults and 50 children. In both methods, the maximum difference of the intraindividual torsional angles and length measurements was 7 degrees and 7 mm. The maximum standard deviation for reproducibility in length measurement was 1.6 mm and 1.5 degrees for angular torsion. The new 3-D US technique was superior to CT in terms of reliability and reproducibility. Clinical advantages of the 3-D US technique include rapidity, independence from patient motion or positioning and the avoidance of ionizing radiation. Indications for 3-D torsional and length determinations include follow-up evaluation of adult and pediatric tibial and femoral fractures, pediatric limb and gait evaluations, and osteotomy planning.

Entities:  

Mesh:

Year:  1999        PMID: 10672602     DOI: 10.1007/s001320050427

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  11 in total

1.  [Analysis and correction of leg deformities. 1: Analysis].

Authors:  W Strecker; P Keppler
Journal:  Unfallchirurg       Date:  2002-09       Impact factor: 1.000

2.  Length and angle measurements of the lower extremity in digital composite overview images.

Authors:  M Boewer; H Arndt; P A W Ostermann; J Petersein; S Mutze
Journal:  Eur Radiol       Date:  2004-05-26       Impact factor: 5.315

3.  Upright MRI measurement of mechanical axis and frontal plane alignment as a new technique: a comparative study with weight bearing full length radiographs.

Authors:  Emmanouil Liodakis; Mohamed Kenawey; Iosifina Doxastaki; Christian Krettek; Carl Haasper; Stefan Hankemeier
Journal:  Skeletal Radiol       Date:  2010-12-18       Impact factor: 2.199

4.  [Clinical results with A new retrograde femoral nail with a radiographical-free proximal locking device. A prospective study with 50 fractures].

Authors:  B Friemert; P Keppler; F von Lübken; C Willy; L Claes; H Gerngross; D Wörz
Journal:  Unfallchirurg       Date:  2005-03       Impact factor: 1.000

Review 5.  [Value of radiographic examination of the knee joint for the orthopedic surgeon].

Authors:  M Pietsch; S Hofmann
Journal:  Radiologe       Date:  2006-01       Impact factor: 0.635

6.  The reverse planning method for lengthening of the lower limb using a straight intramedullary nail with or without deformity correction. A new method.

Authors:  Rainer Baumgart
Journal:  Oper Orthop Traumatol       Date:  2009-06       Impact factor: 1.154

7.  [Femoral nail osteosynthesis. Mechanical factors influencing the femoral antetorsion].

Authors:  M Citak; D Kendoff; M Citak; M J Gardner; M Oszwald; C Krettek; T Hüfner
Journal:  Unfallchirurg       Date:  2008-04       Impact factor: 1.000

8.  [Preventing malrotation during intramedullary nailing of femoral fractures].

Authors:  R E Hilgert; K Ohrendorf; F K W Schäfer; P J Schäfer; M Müller; R Trompetter; H-J Egbers
Journal:  Unfallchirurg       Date:  2006-10       Impact factor: 1.000

9.  [Post-traumatic torsional differences and functional tests following antegrade or retrograde intramedullary nailing of the distal femoral diaphysis].

Authors:  D G Maier; R Reisig; P Keppler; L Kinzl; F Gebhard
Journal:  Unfallchirurg       Date:  2005-02       Impact factor: 1.000

10.  An MRI-based technique for assessment of lower extremity deformities-reproducibility, accuracy, and clinical application.

Authors:  Stefan Hinterwimmer; Heiko Graichen; Thomas J Vogl; Nasreddin Abolmaali
Journal:  Eur Radiol       Date:  2008-03-20       Impact factor: 7.034

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.