Literature DB >> 10670727

Microchip capillary electrophoresis using on-line chemiluminescence detection.

M Hashimoto1, K Tsukagoshi, R Nakajima, K Kondo, A Arai.   

Abstract

Chemiluminescence detection was used in capillary electrophoresis integrated on a microchip. Quartz microchips have two main channels and four reservoirs. Dansyl-lysine and -glycine were separated and detected with bis[(2-(3,6,9-trioxadecanyloxycarbony)-4-nitrophenyl]oxalate as peroxyoxalate chemiluminescent reagent. These dansyl amino acids came into contact with the chemiluminescence reagent to produce visible light at the interface between the separation channel and chemiluminescence reagent-containing reservoir. The detection limit (S/N = 3) for dansyl-lysine was 1 x 10(-5) M, which corresponded to the very small mass detection limit of ca. 0.4 fmol. However, the concentration sensitivity in the present system was approximately two orders of magnitude lower than that in the conventional capillary electrophoresis-chemiluminescence detection system. The relative standard deviations of migration time and peak height for dansyl-lysine were 4.2 and 4.5%, respectively. A channel conditioning before every run and an appropriate control of voltages were needed for the reproducible results. The present system had advantages in rapid separation time (within 40 s), small (several 10 pI) and accurate sample injection method using a cross-shaped injector, and simplification and miniaturization of the detection device.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10670727     DOI: 10.1016/s0021-9673(99)01169-3

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  7 in total

1.  A magnetically active microfluidic device for chemiluminescence bioassays.

Authors:  Yi Zheng; Shulin Zhao; Yi-Ming Liu
Journal:  Analyst       Date:  2011-06-07       Impact factor: 4.616

2.  Integrated Multi-process Microfluidic Systems for Automating Analysis.

Authors:  Weichun Yang; Adam T Woolley
Journal:  JALA Charlottesv Va       Date:  2010-06-01

3.  Chemiluminescence resonance energy transfer-based detection for microchip electrophoresis.

Authors:  Shulin Zhao; Yong Huang; Ming Shi; Rongjun Liu; Yi-Ming Liu
Journal:  Anal Chem       Date:  2010-03-01       Impact factor: 6.986

4.  Electrochemical and optical detectors for capillary and chip separations.

Authors:  Xiaomi Xu; Ling Li; Stephen G Weber
Journal:  Trends Analyt Chem       Date:  2007-01       Impact factor: 12.296

5.  Integrated microfluidic system with chemiluminescence detection for single cell analysis after intracellular labeling.

Authors:  Shulin Zhao; Xiangtang Li; Yi-Ming Liu
Journal:  Anal Chem       Date:  2009-05-15       Impact factor: 6.986

6.  Quantification of carnosine-related peptides by microchip electrophoresis with chemiluminescence detection.

Authors:  Shulin Zhao; Yong Huang; Ming Shi; Junming Huang; Yi-Ming Liu
Journal:  Anal Biochem       Date:  2009-06-16       Impact factor: 3.365

Review 7.  Microchips, Microarrays, Biochips and Nanochips - Personal Laboratories for the 21st Century.

Authors:  Larry J Kricka
Journal:  EJIFCC       Date:  2000-12-28
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.