Literature DB >> 10670032

Experimentally induced nasal irritation.

P Mohammadian1, D Schaefer, T Hummel, G Kobal.   

Abstract

The aim of this study was to develop a method that is suited for the induction of nasal irritation. For this purpose inflammatory responses were analysed after challenging the nasal mucosa with experimentally induced cold, dry air (8 l/min, 22 degrees C, 20 %RH). To assess inflammatory effects we determined inflammatory mediators (prostaglandin E2 [PGE2], thromboxane B2 TXB2[, peptide leukotrienes pLT: LTC4, LTD4, LTE4[) in nasal lavage fluid which was sampled before, immediately after suprathreshold stimulation, and one hour after termination of the stimulation. In addition, subjects estimated the intensity of pain during the stimulation. Cold, dry air produced strong painful sensations which increased throughout the stimulation period. A significant increase of the inflammatory mediator pLT was observed after stimulation; mean concentrations of PGE2 and TXB2 also showed a tendency to increase. One hour after termination of the stimulation the concentration of these inflammatory mediators returned to baseline which indicates the reversibility of the effects of nasal irritation. These data suggest, that this model may be a useful tool in investigations of mucosal irritation as, for example, induced by environmental agents.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10670032

Source DB:  PubMed          Journal:  Rhinology        ISSN: 0300-0729            Impact factor:   3.681


  4 in total

Review 1.  Environmental and non-infectious factors in the aetiology of pharyngitis (sore throat).

Authors:  Bertold Renner; Christian A Mueller; Adrian Shephard
Journal:  Inflamm Res       Date:  2012-08-14       Impact factor: 4.575

2.  Evaluation of eicosanoids in nasal lavage as biomarkers of inflammation in patients with allergic rhinitis.

Authors:  Maciej Ciebiada; Paweł Górski; Adam Antczak
Journal:  Arch Med Sci       Date:  2014-12-22       Impact factor: 3.318

3.  Tonic stimulation of the pharyngeal mucosa causes pain and a reversible increase of inflammatory mediators.

Authors:  Bertold Renner; Gabi Ahne; Elke Grosan; Birgit Kettenmann; Gerd Kobal; Adrian Shephard
Journal:  Inflamm Res       Date:  2013-09-15       Impact factor: 4.575

4.  The effect of different nasal irrigation solutions following septoplasty and concha radiofrequency: a prospective randomized study.

Authors:  Hanifi Kurtaran; K Serife Ugur; Ceyda Sel Yilmaz; Mesut Kaya; Alper Yuksel; Nebil Ark; Mehmet Gunduz
Journal:  Braz J Otorhinolaryngol       Date:  2017-02-22
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.