Literature DB >> 10669673

Decision-tree sensitivity analysis for cost-effectiveness of chest 2-fluoro-2-D-[(18)F]fluorodeoxyglucose positron emission tomography in patients with pulmonary nodules (non-small cell lung carcinoma) in Japan.

S Kosuda1, K Ichihara, M Watanabe, H Kobayashi, S Kusano.   

Abstract

CONTEXT: Recent studies have demonstrated the potential cost-effectiveness of using 2-fluoro-2-D-[(18)F]fluorodeoxyglucose (FDG) positron emission tomography (PET) in the management of non-small cell lung carcinoma (NSCLC), but because of differences in health-care systems, those findings may not hold true in a Japanese hospital.
OBJECTIVE: To assess the cost-effectiveness of the chest CT plus chest FDG-PET strategy in Japan.
DESIGN: Decision-tree sensitivity analysis based on the two competing strategies of chest CT-alone vs chest CT plus chest FDG-PET. STUDY SELECTION: A simulation of 1,000 patients in whom NSCLC, stage IIIB or less, was suspected was created using baselines of other relevant variables in regard to sensitivity, specificity, mortality, life expectancy, and cost from published data.
METHODS: We surveyed the relevant literature for the choice of variables. MAIN OUTCOME MEASURES: Expected marginal cost and expected life expectancy gain for NSCLC patients.
RESULTS: The chest CT plus chest FDG-PET strategy yielded an expected life expectancy gain of 0.607 years (7.3 months) per patient, compared with the alternative strategy of chest CT-alone. Using an FDG-PET examination cost of 1.0 x 10(5) yen (around $700 US) per study, the cost increment was 2.18 x 10(5) yen/yr/patient.
CONCLUSIONS: The chest CT plus chest FDG-PET strategy in patients with NSCLC is unlikely to be cost-effective in Japan. However, patient life expectancy gain would increase as a result of improved staging of NSCLC. These preliminary results should be confirmed by further studies for specific environments.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10669673     DOI: 10.1378/chest.117.2.346

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  7 in total

1.  Requirements for clinical PET: comparisons within Europe.

Authors:  Michael Bedford; Michael N Maisey
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-02       Impact factor: 9.236

2.  Preoperative staging of lung cancer with PET/CT: cost-effectiveness evaluation alongside a randomized controlled trial.

Authors:  Rikke Søgaard; Barbara Malene B Fischer; Jann Mortensen; Liselotte Højgaard; Ulrik Lassen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-01-06       Impact factor: 9.236

Review 3.  A systematic review of PET and PET/CT in oncology: a way to personalize cancer treatment in a cost-effective manner?

Authors:  Astrid Langer
Journal:  BMC Health Serv Res       Date:  2010-10-08       Impact factor: 2.655

4.  Cancer imaging: is it cost-effective?

Authors:  K A Miles
Journal:  Cancer Imaging       Date:  2004-04-06       Impact factor: 3.909

Review 5.  Positron emission tomography-computed tomography in the management of lung cancer: An update.

Authors:  Punit Sharma; Harmandeep Singh; Sandip Basu; Rakesh Kumar
Journal:  South Asian J Cancer       Date:  2013-07

Review 6.  Positron emission tomography scanning for the diagnosis and management of lung cancer.

Authors:  Bruce R Line; Charles S White
Journal:  Curr Treat Options Oncol       Date:  2004-02

7.  Optimal sequence of tests for the mediastinal staging of non-small cell lung cancer.

Authors:  Manuel Luque; Francisco Javier Díez; Carlos Disdier
Journal:  BMC Med Inform Decis Mak       Date:  2016-01-26       Impact factor: 2.796

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.