Literature DB >> 10667527

Capillary blood gases in a pediatric intensive care unit.

R Escalante-Kanashiro1, J Tantaleán-Da-Fieno.   

Abstract

OBJECTIVE: To determine if samples obtained from arterial and capillary sources are comparable in children with diverse pathologic conditions during their stay in a pediatric intensive care unit. STUDY
DESIGN: Prospective, descriptive study in patients admitted to a multidisciplinary pediatric intensive care unit.
INTERVENTIONS: Seventy-five simultaneous paired samples (arterial and capillary) were obtained from patients with different degrees of capillary reperfusion, hemodynamic stability, blood pressure, and temperature. Both samples were analyzed < or =5 mins after collection.
MEASUREMENTS AND MAIN RESULTS: The average correlations between arterial and capillary samples were 0.87 for pH, 0.86 for CO2, and 0.65 for oxygen. Neither poor perfusion nor low temperature altered the correlation for pH or CO2. The only condition that significantly affected the correlation was hypotension.
CONCLUSION: Capillary blood sampling is a useful alternative to gasometric evaluation of critically ill children, even in the presence of hypothermia or hypoperfusion, provided that hypotension is not present.

Entities:  

Mesh:

Year:  2000        PMID: 10667527     DOI: 10.1097/00003246-200001000-00037

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  6 in total

1.  Non-invasive carbon dioxide monitoring in patients with cystic fibrosis during general anesthesia: end-tidal versus transcutaneous techniques.

Authors:  Anne May; Chris Humston; Julie Rice; Christopher J Nemastil; Ann Salvator; Joseph Tobias
Journal:  J Anesth       Date:  2019-11-07       Impact factor: 2.078

2.  Correlation of simultaneously obtained capillary, venous, and arterial blood gases of patients in a paediatric intensive care unit.

Authors:  D Yildizdaş; H Yapicioğlu; H L Yilmaz; Y Sertdemir
Journal:  Arch Dis Child       Date:  2004-02       Impact factor: 3.791

3.  Prediction of arterial blood gas values from arterialized earlobe blood gas values in patients treated with mechanical ventilation.

Authors:  Azim Honarmand; Mohammadreza Safavi
Journal:  Indian J Crit Care Med       Date:  2008-07

4.  Monitoring Oxygenation and Gas Exchange in Neonatal Intensive Care Units: Current Practice in the Netherlands.

Authors:  Ratna N G B Tan; Estelle E M Mulder; Enrico Lopriore; Arjan B Te Pas
Journal:  Front Pediatr       Date:  2015-11-03       Impact factor: 3.418

5.  Correlation and Interchangeability of Venous and Capillary Blood Gases in Non-Critically Ill Neonates.

Authors:  Ratna N G B Tan; Steffen C Pauws; Evelyne van Loon; Vivanne E H J Smits; Enrico Lopriore; Arjan B Te Pas
Journal:  Front Pediatr       Date:  2018-04-12       Impact factor: 3.418

6.  Agreement between Arterial and Capillary pH, pCO2, and Lactate in Patients in the Emergency Department.

Authors:  Vincent Collot; Stefano Malinverni; Jabir Haltout; Eric Schweitzer; Pierre Mols; Magali Bartiaux
Journal:  Emerg Med Int       Date:  2021-07-06       Impact factor: 1.112

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.