Literature DB >> 10666749

The first year experience with the dual chamber ICD.

S L Higgins1, J P Pak, J Barone, S K Williams, F M Bollinger, S L Whiting, D B Meyer.   

Abstract

In July 1997, a dual chamber pacemaker combined with a tiered therapy implantable cardioverter defibrillator (ICD) first became available in the United States. We report the first-year experience of one center in the United States with this dual chamber ICD. Of a total of 174 ICDs, 95 (55%) were dual chamber devices and 79 (45%) were single chamber. New dual chamber ICD insertions averaged 57.4 +/- 8.9 minutes, though there was a learning curve as the last 30 implants averaged 45.1 +/- 6.1 minutes with a negative slope to the regression line of procedure duration (-0.52, P < 0.05). New single chamber ICD implants were 18.5 minutes quicker (38.9 +/- 7.2 minutes). The most challenging implants were dual chamber upgrades (mean procedure duration 64.9 +/- 15.8 minutes), especially if there was a previously implanted pacemaker and ICD at separate sites. Indications for a new dual chamber device were grouped into classic pacemaker indications (52.5%), which comprised the Class I ACC/AHA guidelines, ICD-specific indications (24.6%), and other (23.0%). In the 34 patients undergoing dual chamber upgrade, the classic and ICD-specific groups were equal (47.0% each). Complications were rare (2.8%), though 3 (8.8%) of 34 undergoing a dual chamber upgrade developed late infections requiring explantation. In its first year, the dual chamber ICD has become a common device at our institution comprising 55% of new implants. As experience grows, we anticipate similar usage at most institutions.

Entities:  

Mesh:

Year:  2000        PMID: 10666749     DOI: 10.1111/j.1540-8159.2000.tb00645.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

1.  Characterization of the 16 blanking periods of the Medtronic GEM DR dual chamber defibrillators.

Authors:  S S Barold; F Cantens
Journal:  J Interv Card Electrophysiol       Date:  2001-09       Impact factor: 1.900

2.  Volume, outcome, and policy.

Authors:  Mark A Hlatky
Journal:  J Interv Card Electrophysiol       Date:  2012-12-18       Impact factor: 1.900

Review 3.  Should all implantable cardioverter defibrillators for ventricular arrhythmias be dual-chamber devices?

Authors:  K L Lee; C P Lau
Journal:  Curr Cardiol Rep       Date:  2001-11       Impact factor: 2.931

4.  Iranian Patients' Experiences of the Internal Cardioverter Defibrillator Device Shocks: a Qualitative Study.

Authors:  Nilofar Pasyar; Farkhondeh Sharif; Mahnaz Rakhshan; Mohammad Nikoo; Elham Navab
Journal:  J Caring Sci       Date:  2015-12-01
  4 in total