Literature DB >> 10665677

Mechatronic assessment of arm impairment after chronic brain injury.

D J Reinkensmeyer1, B D Schmit, W Z Rymer.   

Abstract

Significant potential exists for mechatronic devices to improve assessment and treatment of individuals with a movement disability following stroke, traumatic brain injury, or cerebral palsy. We report the use of a mechatronic device for evaluation of the arm after chronic brain injury. We performed a series of experiments with the device in order to identify the relative contribution of three different motor impairments to decreased active range of motion of reaching in five brain-injured subjects. Our findings were that passive tissue restraint and agonist weakness, rather than antagonist restraint, were the most common contributors to decreased active range of motion. These results demonstrate the feasibility of objective assessment of functional movement using a mechatronic device, and could provide the basis for improved, individualized treatment planning and monitoring following brain injury.

Entities:  

Mesh:

Year:  1999        PMID: 10665677

Source DB:  PubMed          Journal:  Technol Health Care        ISSN: 0928-7329            Impact factor:   1.285


  5 in total

Review 1.  Robot-aided neurorehabilitation of the upper extremities.

Authors:  R Riener; T Nef; G Colombo
Journal:  Med Biol Eng Comput       Date:  2005-01       Impact factor: 2.602

2.  Component-Level Tuning of Kinematic Features From Composite Therapist Impressions of Movement Quality.

Authors:  Vinay Venkataraman; Pavan Turaga; Michael Baran; Nicole Lehrer; Tingfang Du; Long Cheng; Thanassis Rikakis; Steven L Wolf
Journal:  IEEE J Biomed Health Inform       Date:  2014-11-26       Impact factor: 5.772

3.  Design and Characterization of Hand Module for Whole-Arm Rehabilitation Following Stroke.

Authors:  L Masia; Hermano Igo Krebs; P Cappa; N Hogan
Journal:  IEEE ASME Trans Mechatron       Date:  2007-08-01       Impact factor: 5.303

Review 4.  Upper Limb Motor Impairment After Stroke.

Authors:  Preeti Raghavan
Journal:  Phys Med Rehabil Clin N Am       Date:  2015-08-25       Impact factor: 1.784

5.  A robotic object hitting task to quantify sensorimotor impairments in participants with stroke.

Authors:  Kathrin Tyryshkin; Angela M Coderre; Janice I Glasgow; Troy M Herter; Stephen D Bagg; Sean P Dukelow; Stephen H Scott
Journal:  J Neuroeng Rehabil       Date:  2014-04-02       Impact factor: 4.262

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.