Preoperative manual detorsion of the spermatic cord with Doppler ultrasound monitoring in patients with intravaginal acute testicular torsion.

L Garel1, J Dubois, G Azzie, D Filiatrault, A Grignon, S Yazbeck.   

Abstract

OBJECTIVE: To assess the effectiveness of preoperative manual detorsion in acute testicular torsion.
MATERIALS AND METHODS: Between June 1998 and March 1999, seven patients presenting with testicular torsion underwent manual manipulation under US monitoring in order to restore the flow to the testis prior to surgery (orchidopexy). All detorsions were lateral in direction. The success of the manoeuvre was assessed both clinically and sonographically and confirmed at surgery.
RESULTS: Six manoeuvres were successful in restoring flow to the testis. The failed attempt in the seventh patient was due to failure to manipulate beyond an initial 1 1/2 rotations (540 degrees).
CONCLUSIONS: Preoperative detorsion is the fastest way to relieve testicular ischaemia. However, manual detorsion of the spermatic cord is not a substitute for surgical exploration and bilateral orchidopexy is still necessary.

Entities:  

Mesh:

Year:  2000        PMID: 10663509     DOI: 10.1007/s002470050012

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  6 in total

1.  A novel approach for manual de-torsion of an atypical (outward) testicular torsion with bedside Doppler ultrasonography guidance.

Authors:  Mustafa Güneş; Mehmet Umul; Ahmet Orhan Çelik; Hamit Hakan Armağan; Bumin Değirmenci
Journal:  Can Urol Assoc J       Date:  2015-09-09       Impact factor: 1.862

Review 2.  Scrotal emergencies.

Authors:  Matteo Baldisserotto
Journal:  Pediatr Radiol       Date:  2009-02-03

3.  Acute testicular torsion in children: the role of sonography in the diagnostic workup.

Authors:  P Gunther; J P Schenk; R Wunsch; S Holland-Cunz; U Kessler; J Troger; K L Waag
Journal:  Eur Radiol       Date:  2006-05-25       Impact factor: 7.034

4.  The Effects of Fentanyl on Testicular Ischemia-Reperfusion Injury.

Authors:  Cengiz Mordeniz; Mahluga Jafarova Demirkapu; Hacı Murat Akgul; Sevil Karabag; Aliye Celikkol; Hasan Raci Yananlı
Journal:  Turk J Anaesthesiol Reanim       Date:  2021-10

5.  The Monitoring of Preoperative External Detorsion with Diffusion-Weighted Imaging in a Patient with Acute Testicular Torsion.

Authors:  Mehmet Beyazal; Fatma Beyazal Çeliker; Mehmet Fatih İnecikli; Maksude Esra Kadioğlu; Hasan Rıza Aydın; Tuğba Durakoğlugil
Journal:  Case Rep Radiol       Date:  2017-08-28

6.  The effectiveness of extra-scrotal fixation following manual detorsion for testicular torsion: a pilot study in a rabbit model.

Authors:  Mustafa Güneş; Muammer Altok; Özlem Özmen; Bumin Değirmenci; Zafer Özyildiz; Ercan Baş; Mustafa Kara; Cevdet Kaya
Journal:  Cent European J Urol       Date:  2016-11-30
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.