Literature DB >> 10663283

Comprehensive critical incident monitoring in a neonatal-pediatric intensive care unit: experience with the system approach.

B Frey1, B Kehrer, M Losa, H Braun, L Berweger, J Micallef, M Ebenberger.   

Abstract

OBJECTIVE: To examine the occurrence of critical incidents (CIs) in order to improve quality of care.
DESIGN: Prospective survey.
SETTING: Multidisciplinary, neonatal-pediatric intensive care unit (ICU) of a non-university, teaching children's hospital. PATIENTS: Four hundred and sixty-seven admissions over a 1-year period.
METHODS: A CI is any event which could have reduced, or did reduce, the safety margin for the patient. Comprehensive, anonymous, non-punitive CI monitoring was undertaken. CI severity with respect to actual patient harm was graded: major (score 3), moderate (2) or minor (1). The system approach incorporates the philosophy that errors are evidence of deficiencies in systems, not in people. We undertook 2-monthly analyses of CIs.
RESULTS: There were 211 CI reports: 30 % major, 25 % moderate, 45 % minor. The CI categories were management/environment 29 %, drugs 29 %, procedures 18 %, respiration 14 %, equipment dysfunction 7 %, nosocomial infections 3 %. The respiratory CIs were the most severe, the drug-related CIs the least severe (score mean, SD: 2.9, 0.26 vs 1.4, 0.76; p < 0.001). However, 20 out of 62 drug-related CIs were potentially life-threatening. Thirteen percent of drug CIs were decimal point errors. Eleven of the 29 respiratory CIs were accidental extubations (2.6/100 ventilator days). CIs were most often precipitated by consultants (32 %), followed by residents (23 %, over-represented in drug CIs, 22/62) and specialized nurses (21 %). Doctors had a greater proportion of major CIs than nurses (p < 0.01). Fifty percent of the CIs were detected by routine checks. The most important method of detection was patient inspection (44 %), alarms accounted for only 10 %. Contributing factors were human errors (63 %), communication failure (14 %), organizational problems (10 %), equipment dysfunction (7 %) and milieu (3 %).
CONCLUSIONS: CIs are very common in pediatric intensive care. Knowledge of them is a precious source for quality improvement through changes in the system.

Entities:  

Mesh:

Year:  2000        PMID: 10663283     DOI: 10.1007/s001340050014

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  18 in total

Review 1.  Safe paediatric intensive care. Part 2: workplace organisation, critical incident monitoring and guidelines.

Authors:  Bernhard Frey; Andrew Argent
Journal:  Intensive Care Med       Date:  2004-04-30       Impact factor: 17.440

2.  Adverse events in a paediatric intensive care unit: relationship to workload, skill mix and staff supervision.

Authors:  Shane M Tibby; Joanna Correa-West; Andrew Durward; Lesley Ferguson; Ian A Murdoch
Journal:  Intensive Care Med       Date:  2004-04-06       Impact factor: 17.440

3.  Incident reports versus direct observation to identify medication errors and risk factors in hospitalised newborns.

Authors:  David Palmero; Ermindo R Di Paolo; Corinne Stadelmann; André Pannatier; Farshid Sadeghipour; Jean-François Tolsa
Journal:  Eur J Pediatr       Date:  2018-11-21       Impact factor: 3.183

4.  Paediatric critical incident analysis: lessons learnt on analysis, recommendations and implementation.

Authors:  Cynthia van der Starre; Monique van Dijk; Ada van den Bos; Dick Tibboel
Journal:  Eur J Pediatr       Date:  2014-05-31       Impact factor: 3.183

Review 5.  Incidents and errors in neonatal intensive care: a review of the literature.

Authors:  C Snijders; R A van Lingen; A Molendijk; W P F Fetter
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2007-03-21       Impact factor: 5.747

6.  Early detection of deteriorating ventilation by monitoring bilateral chest wall dynamics in the rabbit.

Authors:  Dan Waisman; Anna Faingersh; Carmit Levy; Eugene Konyukhov; Fatmi Ifat Colman Klotzman; Avi Rotschild; Amir Landesberg
Journal:  Intensive Care Med       Date:  2011-11-22       Impact factor: 17.440

7.  Factors associated with iatrogenesis in neonatal intensive care units: an observational multicenter study.

Authors:  Einav Srulovici; Liora Ore; Eric S Shinwell; Shraga Blazer; Shmuel Zangen; Arieh Riskin; David Bader; Amir Kugelman
Journal:  Eur J Pediatr       Date:  2012-07-28       Impact factor: 3.183

8.  Critical incidents in paediatric critical care: who is at risk?

Authors:  Oliver W Niesse; Felix H Sennhauser; Bernhard Frey
Journal:  Eur J Pediatr       Date:  2010-09-09       Impact factor: 3.183

Review 9.  Safe paediatric intensive care. Part 1: Does more medical care lead to improved outcome?

Authors:  Bernhard Frey; Andrew Argent
Journal:  Intensive Care Med       Date:  2004-04-22       Impact factor: 17.440

10.  Medication safety in neonatal care: a review of medication errors among neonates.

Authors:  Natalia Krzyzaniak; Beata Bajorek
Journal:  Ther Adv Drug Saf       Date:  2016-04-01
View more