Literature DB >> 10662499

A reusable and specific protein A-coated piezoelectric biosensor for flow injection immunoassay.

H C Lu1, H M Chen, Y S Lin, J W Lin.   

Abstract

A hydrophilic matrix of periodate-oxidized dextran was used as a double-sided linker to covalently immobilize Staphylococcus aureus protein A (SpA) molecules onto a poly-L-lysine-modified piezoelectric crystal surface to improve their stability, activity, and binding specificity with human immunoglobulin G (IgG) in flow injection assays. The prepared sensing crystals displayed best sensitivity and reusability at a flow rate of 140 microL/min. A human IgG concentration as low as 0.3 nM can be detected by this system. Up to 19 successive assay repetitions were achieved without significant loss of sensitivity using the same crystal. The analysis of adsorption kinetics indicates that such a preparation can greatly increase the amount of available active human IgG binding sites on immobilized SpA. Hardly any response arising from unspecific binding was detected. In addition, the sensing crystal prepared by this method was found to retain activity better than one prepared via direct deposition when stored in either wet or dry states. Finally, the prepared SpA-coated crystals were applied to the affinity immobilization of polyclonal goat anti-Schistosoma japonicum glutathione-S-transferase (GST) and were able to subsequently detect GST and its genetically engineered mutant either in a purified form or in the crude cell lysate.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10662499     DOI: 10.1021/bp9901320

Source DB:  PubMed          Journal:  Biotechnol Prog        ISSN: 1520-6033


  4 in total

Review 1.  Guide to Selecting a Biorecognition Element for Biosensors.

Authors:  Marissa A Morales; Jeffrey Mark Halpern
Journal:  Bioconjug Chem       Date:  2018-09-28       Impact factor: 4.774

2.  Immobilization of Bioactive Protein A from Staphylococcus aureus (SpA) on the Surface of Bacillus subtilis Spores.

Authors:  Samira Ghaedmohammadi; Garshasb Rigi; Reza Zadmard; Ezio Ricca; Gholamreza Ahmadian
Journal:  Mol Biotechnol       Date:  2015-08       Impact factor: 2.695

Review 3.  Nanotechnology-Based Surface Plasmon Resonance Affinity Biosensors for In Vitro Diagnostics.

Authors:  Riccarda Antiochia; Paolo Bollella; Gabriele Favero; Franco Mazzei
Journal:  Int J Anal Chem       Date:  2016-08-10       Impact factor: 1.885

4.  A piezoelectric immunosensor using hybrid self-assembled monolayers for detection of Schistosoma japonicum.

Authors:  Shiping Wang; Tieqiu Yin; Shaohua Zeng; Hongli Che; Feifei Yang; Xiuchun Chen; Guoli Shen; Zhaoyang Wu
Journal:  PLoS One       Date:  2012-01-27       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.