Literature DB >> 10661523

Objective assessment of limb tissue elasticity: development of a manual indentation procedure.

Y Zheng1, A F Mak, B Lue.   

Abstract

An ultrasound indentation system with a pen-size hand-held probe was developed and used to obtain the effective Young's moduli of forearm and lower limb soft tissues in 12 subjects. Since the probe is manually driven, the alignment of the probe and control of the rate of indentation are parameters upon which the results obtained depend. This paper addresses whether manual indentation tests with the probe are sufficiently acceptable and repeatable for objective biomechanical characterization of limb tissues. Forearms of three normal subjects were tested in two states of muscular contraction. Six different indentation rates, ranging from 0.75 mm/s to 7.5 mm/s, were imposed. The load-indentation responses obtained were shown to be well represented by quadratic functions. A linear elastic indentation solution was used to extract the effective Young's modulus. The material parameters extracted were repeatable and rather rate-insensitive for the range of rates used. The effective Young's modulus obtained was found to significantly increase as a result of contraction of the underlying muscles. Indentor misalignment experiments demonstrated that misalignment affects the measurement from which the effective Young's modulus of soft tissues is calculated. This effect, however, was found to decrease as the tissue thickness increased. With the investigation of the above issues, a procedure has been established for the extraction of effective Young's moduli of limb soft tissues from manual cyclic indentation responses. Tests on experimental subjects' lower limbs further demonstrated that the ultrasonic indentor is a feasible instrument for characterization of the biomechanical properties of limb soft tissues. Paired-t tests showed that the effective Young's moduli of the lower limb soft tissues of three elderly persons with transtibial amputation were significantly smaller than those of six unimpaired young subjects.

Entities:  

Mesh:

Year:  1999        PMID: 10661523

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  19 in total

1.  Assessment of neck tissue fibrosis using an ultrasound palpation system: a feasibility study.

Authors:  Y P Zheng; S F Leung; A F Mak
Journal:  Med Biol Eng Comput       Date:  2000-09       Impact factor: 2.602

2.  Indentation test of soft tissues with curved substrates: a finite element study.

Authors:  M H Lu; Y P Zheng
Journal:  Med Biol Eng Comput       Date:  2004-07       Impact factor: 2.602

3.  Estimation of Young's modulus and Poisson's ratio of soft tissue from indentation using two different-sized indentors: finite element analysis of the finite deformation effect.

Authors:  A P C Choi; Y P Zheng
Journal:  Med Biol Eng Comput       Date:  2005-03       Impact factor: 2.602

4.  Modeling and preliminary testing socket-residual limb interface stiffness of above-elbow prostheses.

Authors:  Jonathon W Sensinger; Richard F ff Weir
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2008-04       Impact factor: 3.802

5.  Risk and injury severity of obese child passengers in motor vehicle crashes.

Authors:  Jong-Eun Kim; Min-Heng Hsieh; Phillip C Shum; R Shane Tubbs; David B Allison
Journal:  Obesity (Silver Spring)       Date:  2015-02-03       Impact factor: 5.002

6.  Measurement of the layered compressive properties of trypsin-treated articular cartilage: an ultrasound investigation.

Authors:  Y P Zheng; C X Ding; J Bai; A F Mak; L Qin
Journal:  Med Biol Eng Comput       Date:  2001-09       Impact factor: 2.602

7.  An optical coherence tomography (OCT)-based air jet indentation system for measuring the mechanical properties of soft tissues.

Authors:  Yan-Ping Huang; Yong-Ping Zheng; Shu-Zhe Wang; Zhong-Ping Chen; Qing-Hua Huang; Yong-Hong He
Journal:  Meas Sci Technol       Date:  2009-01       Impact factor: 2.046

8.  Effect of Local Neck Anatomy on Localized One-Dimensional Measurements of Arterial Stiffness: A Finite-Element Model Study.

Authors:  Adriaan Campo; Matthew D McGarry; Thomas Panis; Joris Dirckx; Elisa Konofagou
Journal:  J Biomech Eng       Date:  2019-03-01       Impact factor: 2.097

9.  A computational study of injury severity and pattern sustained by overweight drivers in frontal motor vehicle crashes.

Authors:  Jong-Eun Kim; Il Hwan Kim; Phillip C Shum; Alan M Shih; Frank Pintar; Wei Shen; Xiaoguang Ma; Purushottam W Laud; Steven B Heymsfield; David B Allison; Shankuan Zhu
Journal:  Comput Methods Biomech Biomed Engin       Date:  2012-10-31       Impact factor: 1.763

10.  Influence of a soft tissue layer covering the kidney upon blunt impact.

Authors:  Lea Siegenthaler; Florian Sprenger; Fabiano Riva; Matthieu J Glardon; Beat P Kneubuehl; Martin Frenz
Journal:  Int J Legal Med       Date:  2019-07-09       Impact factor: 2.686

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.