Literature DB >> 10661339

Extracranial stereotactic radiation therapy: set-up accuracy of patients treated for liver metastases.

K K Herfarth1, J Debus, F Lohr, M L Bahner, P Fritz, A Höss, W Schlegel, M F Wannenmacher.   

Abstract

PURPOSE: Patients with liver metastases might benefit from high-dose conformal radiation therapy. A high accuracy of repositioning and a reduction of target movement are necessary for such an approach. The set-up accuracy of patients with liver metastases treated with stereotactic single dose radiation was evaluated. METHODS AND MATERIALS: Twenty-four patients with liver metastases were treated with single dose radiation therapy on 26 occasions using a self-developed stereotactic frame. Liver movement was reduced by abdominal pressure. The effectiveness was evaluated under fluoroscopy. CT scans were performed on the planning day and directly before treatment. Representative reference marks were chosen and the coordinates were calculated. In addition, the target displacement was quantitatively evaluated after treatment.
RESULTS: Diaphragmal movement was reduced to median 7 mm (range: 3-13 mm). The final set-up accuracy of the body was limited to all of median 1.8 mm in latero-lateral direction (range: 0.3-5.0 mm) and 2.0 mm in anterior-posterior direction (0.8-3.8 mm). Deviations of the body in cranio-caudal direction were always less than the thickness of one CT slice (<5 mm). However, a repositioning was necessary in 16 occasions. The final target shift was median 1.6 mm (0.2-7.0 mm) in latero-lateral and 2.3 mm in anterior-posterior direction (0.0-6.3 mm). The median shift in cranio-caudal direction was 4.4 mm (0.0-10.0 mm).
CONCLUSIONS: In patients with liver metastases, a high set-up accuracy of the body and the target can be achieved. This allows a high-dose focal radiotherapy of these lesions. However, a control CT scan should be performed directly before therapy to confirm set-up accuracy and possibly prompt necessary corrections.

Entities:  

Mesh:

Year:  2000        PMID: 10661339     DOI: 10.1016/s0360-3016(99)00413-7

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  39 in total

Review 1.  Imaging and image-guided radiation therapy in liver cancer.

Authors:  Kristy K Brock
Journal:  Semin Radiat Oncol       Date:  2011-10       Impact factor: 5.934

Review 2.  [Radiotherapy of hepatic metastases].

Authors:  S E Combs; K K Herfarth; D Habermehl; J Debus
Journal:  Chirurg       Date:  2010-06       Impact factor: 0.955

3.  Digital tomosynthesis for respiratory gated liver treatment: clinical feasibility for daily image guidance.

Authors:  Q Jackie Wu; Jeffrey Meyer; Jessica Fuller; Devon Godfrey; Zhiheng Wang; Junan Zhang; Fang-Fang Yin
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-06-18       Impact factor: 7.038

4.  [Stereotactic radiation therapy for liver metastases].

Authors:  K K Herfarth; J Debus
Journal:  Chirurg       Date:  2005-06       Impact factor: 0.955

5.  An orthotopic lung tumor model for image-guided microirradiation in rats.

Authors:  Debabrata Saha; Linda Watkins; Yi Yin; Philip Thorpe; Michael D Story; Kwang Song; Pavithra Raghavan; Robert Timmerman; Benjamin Chen; John D Minna; Timothy D Solberg
Journal:  Radiat Res       Date:  2010-07       Impact factor: 2.841

6.  Imaged-guided liver stereotactic body radiotherapy using VMAT and real-time adaptive tumor gating. Concerns about technique and preliminary clinical results.

Authors:  Carmen Llacer-Moscardo; Olivier Riou; David Azria; Ludovic Bedos; Norbert Ailleres; Francois Quenet; Philippe Rouanet; Marc Ychou; Pascal Fenoglietto
Journal:  Rep Pract Oncol Radiother       Date:  2016-09-05

Review 7.  Stereotactic radiotherapy in the liver hilum. Basis for future studies.

Authors:  C Zamboglou; M-B Messmer; G Becker; F Momm
Journal:  Strahlenther Onkol       Date:  2011-12-24       Impact factor: 3.621

8.  Stereotactic body radiation therapy (SBRT) for treatment of adrenal gland metastases from non-small cell lung cancer.

Authors:  Richard Holy; Marc Piroth; Michael Pinkawa; Michael J Eble
Journal:  Strahlenther Onkol       Date:  2011-03-21       Impact factor: 3.621

9.  Safety margin in irradiation of colorectal liver metastases: assessment of the control dose of micrometastases.

Authors:  Max Seidensticker; Peter Wust; Ricarda Rühl; Konrad Mohnike; Maciej Pech; Gero Wieners; Günther Gademann; Jens Ricke
Journal:  Radiat Oncol       Date:  2010-03-24       Impact factor: 3.481

Review 10.  [Stereotactic irradiation of lung tumors].

Authors:  H Hof; K Herfarth; J Debus
Journal:  Radiologe       Date:  2004-05       Impact factor: 0.635

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.