Literature DB >> 10660989

Development of a continuous monitoring system for PM10 and components of PM2.5.

M Lippmann1, J Q Xiong, W Li.   

Abstract

While particulate matter with aerodynamic diameters below 10 and 2.5 microns (PM10 and PM2.5) correlate with excess mortality and morbidity, there is evidence for still closer epidemiological associations with sulfate ion, and experimental exposure-response studies suggest that the hydrogen ion and ultrafine (PM0.15) concentrations may be important risk factors. Also, there are measurement artifacts in current methods used to measure ambient PM10 and PM2.5, including negative artifacts because of losses of sampled semivolatile components (ammonium nitrate and some organics) and positive artifacts due to particle-bound water. To study such issues, we are developing a semi-continuous monitoring system for PM10, PM2.5, semivolatiles (organic compounds and NH4NO3), particle-bound water, and other PM2.5 constituents that may be causal factors. PM10 is aerodynamically sorted into three size-fractions: (1) coarse (PM10-PM2.5); (2) accumulation mode (PM2.5-PM0.15); and (3) ultrafine (PM0.15). The mass concentration of each fraction is measured in terms of the linear relation between accumulated mass and pressure drop on polycarbonate pore filters. The PM0.15 mass, being highly correlated with the ultrafine number concentration, provides a good index of the total number concentration in ambient air. For the accumulation mode (PM2.5-PM0.15), which contains nearly all of the semivolatiles and particle-bound water by mass, aliquots of the aerosol stream flow into system components that continuously monitor sulfur (by flame photometry), ammonium and nitrate (by chemiluminescence following catalytic transformations to NO), organics (by thermal-optical analysis) and particle-bound water (by electrolytic hygrometer after vacuum evaporation of sampled particles). The concentration of H+ can be calculated (by ion balance using the monitoring data on NO3-, NH4+, and SO4=).

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10660989     DOI: 10.1080/104732200301854

Source DB:  PubMed          Journal:  Appl Occup Environ Hyg        ISSN: 1047-322X


  1 in total

1.  Aerosol chemistry over a high altitude station at northeastern Himalayas, India.

Authors:  Abhijit Chatterjee; Anandamay Adak; Ajay K Singh; Manoj K Srivastava; Sanjay K Ghosh; Suresh Tiwari; Panuganti C S Devara; Sibaji Raha
Journal:  PLoS One       Date:  2010-06-16       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.