Literature DB >> 10659748

Monte Carlo calculations of dose rate distributions around the Amersham CDCS-M-type 137Cs source.

E Casal1, F Ballester, J L Lluch, J Pérez-Calatayud, F Lliso.   

Abstract

The Amersham CDCS-M-type 137Cs stainless-steel encapsulated source is widely used in low dose rate brachytherapy with manual afterloading. However there is a need for more accurate dosimetry data. In this study we present Monte Carlo calculations of absolute dose rate in water around this source using the Monte Carlo code GEANT, discuss dosimetric features of these data, and compare them with Krishnaswamy's results for 137Cs intracavitary sources. Dose rate distributions are presented in the form of along-away tables and in the TG43 formalism. Simulated absolute dose rate values can be used as benchmark data to verify the treatment planning system calculation results or directly as input data for treatment planning. Best-fit values of attenuation coefficients suitable for use in Sievert integral type calculations have been derived comparing dose rate distributions calculated using this algorithm with those obtained from Monte Carlo calculations.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10659748     DOI: 10.1118/1.598875

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  An analytic approach to the dosimetry of a new BEBIG (60)Co high-dose-rate brachytherapy source.

Authors:  Subhalaxmi Bhola; T Palani Selvam; Sahoo Sridhar; Ramkrishna S Vishwakarma
Journal:  J Med Phys       Date:  2012-07

2.  Establishment of air kerma reference standard for low dose rate Cs-137 brachytherapy sources.

Authors:  Sunil Dutt Sharma; Sudhir Kumar; P Srinivasan; G Chourasiya
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

3.  Dosimetric evaluation of a newly designed low dose rate brachytherapy applicator for treatment of cervical cancer with extension into the lower vagina.

Authors:  Curtis Baker; Sharifeh A Dini; Mahesh Kudrimoti; Shahid B Awan; Ali S Meigooni
Journal:  J Appl Clin Med Phys       Date:  2007-04-19       Impact factor: 2.102

4.  The effect of tandem-ovoid titanium applicator on points A, B, bladder, and rectum doses in gynecological brachytherapy using 192Ir.

Authors:  Mohammad Hosein Sadeghi; Sedigheh Sina; Amir Mehdizadeh; Reza Faghihi; Vahed Moharramzadeh; Ali Soleimani Meigooni
Journal:  J Contemp Brachytherapy       Date:  2018-02-28
  4 in total