UNLABELLED: Three-dimensional echocardiography and magnetic resonance imaging allow the volumetric analysis of ventricular volumes independent of geometric assumptions. The aim of the study was to compare these methods and the common angiocardiography in a cardiac model of known volume. METHODS/MATERIALS: Right and left ventricular (RV, LV-) volumes were measured in a specific animal model directly ('true volume') and with different imaging techniques. Three-dimensional echocardiography (3D-Echo) and magnetic resonance imaging (MRI), both of which permit a volume estimation without necessitating geometric assumptions, and angiocardiographic volumetry which is based on the Simpson rule were used in this study.
RESULTS: The best results were achieved with MRI (RV: r(2)=0.99, mean difference: -1. 9+/-3.3%; LV: difference r(2)=0.99,: 2.9+/-5.0%). Likewise, 3D-Echo showed a very good correlation with the true volumes (RV: r(2)=0.93, difference: 9.3+/-6.3%; LV r(2)=0.96, difference: 4.8+/-9.9%). The greatest deviations were observed during angiocardiographic volumetry (LV: r(2)=0.98; difference: 14.4+/-9.2%), particularly when measuring the right ventricle (RV: r(2)=0.82, difference: 57. 9+/-40.1%). Consequently, the direct comparison between 3D-Echo and the other methods yielded the best correspondence with MRI (RV: Bias: 3.7 ml, limits of agreement: 7.7 ml; LV: Bias: 3.7 ml, limits of agreement: 4.9 ml). In contrast, the differences between 3D-Echo and angiocardiography were marked (RV: Bias: 25.5 ml, limits of agreement: 11.1 ml; LV: Bias: 8.7 ml, limits of agreement: 13.2 ml).
CONCLUSION: In a porcine cardiac model, 3D-Echo permits a relatively precise measurement of ventricular volumes with a slight under-estimation. MRI yielded the most precise volumetry, and the correlation between 3D-Echo and MRI was quite good. Particularly for the right ventricle, the angiocardiographic measurement was attached with the greatest error and thus appears ill-suited for the volumetry of geometrically more complex ventricles.

Mesh:

Year:  1999        PMID: 10657599     DOI: 10.1016/s0929-8266(99)00032-4

Source DB:  PubMed          Journal:  Eur J Ultrasound        ISSN: 0929-8266


  6 in total

1.  A simple single slice method for measurement of left and right ventricular enlargement by electron beam tomography.

Authors:  S Mao; M J Budoff; R J Oudiz; H Bakhsheshi; S Wang; B H Brundage
Journal:  Int J Card Imaging       Date:  2000-10

2.  In vitro determination of cardiac ventricular volumes using MRI at 1.0 T in a porcine heart model.

Authors:  J A Koch; L W Poll; E Godehardt; B Korbmacher; G Jung; U Mödder
Journal:  Int J Cardiovasc Imaging       Date:  2001-06       Impact factor: 2.357

3.  Measurement of left ventricular volumes and ejection fraction by quantitative gated SPET, contrast ventriculography and magnetic resonance imaging: a meta-analysis.

Authors:  Chisato Kondo; Kenji Fukushima; Kiyoko Kusakabe
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-04-04       Impact factor: 9.236

Review 4.  The emerging role of MRI in the diagnosis and management of cardiomyopathies.

Authors:  Carlos Eduardo Rochitte; Eduardo Marinho Tassi; Afonso Akio Shiozaki
Journal:  Curr Cardiol Rep       Date:  2006-02       Impact factor: 2.931

5.  Rapid and accurate quantification of right ventricular volume and stroke volume by real-time 3-dimensional triplane echocardiography.

Authors:  Ya-Ni Liu; You-Bin Deng; Bing-Bing Liu; Qing-Yang Zhang
Journal:  Clin Cardiol       Date:  2008-08       Impact factor: 2.882

6.  5/6 Area length method for left-ventricular ejection-fraction measurement in adults with repaired tetralogy of Fallot: comparison with cardiovascular magnetic resonance.

Authors:  Jimmy C Lu; Gregory J Ensing; Sunkyung Yu; Thor Thorsson; Janet E Donohue; Adam L Dorfman
Journal:  Pediatr Cardiol       Date:  2012-07-14       Impact factor: 1.655

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.