PURPOSE: The purpose of this study was to measure improvement in best corrected visual acuity with rigid gas permeable (RGP) contact lenses compared to best corrected spectacle visual acuity for patients with irregular astigmatism.
METHODS: We compared best corrected visual acuity obtained with spectacle correction to best corrected visual acuity obtained with rigid gas permeable contact lenses for forty-eight eyes of 29 patients with irregular astigmatism.
RESULTS: Patients with 20/20 spectacle visual acuity achieved, on average, no improvement in visual acuity with RGP contact lenses. Patients with 20/25-20/30 spectacle visual acuity achieved a one line average improvement. Patients with 20/40 spectacle visual acuity achieved a two line average improvement. Patients with 20/50-20/200 spectacle visual acuity achieved a four line average improvement and patients with spectacle visual acuity of 20/400, a six line average improvement.
CONCLUSIONS: RGP contact lenses can provide a significant improvement in visual acuity compared to spectacle correction for patients with irregular astigmatism.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10656303

Source DB:  PubMed          Journal:  CLAO J        ISSN: 0733-8902


  4 in total

1.  Mushroom keratoplasty and contact lens application: Strategy for management of a pediatric eye injury.

Authors:  Saverio V Luccarelli; Stefano Lucentini; Francesco Bonsignore; Paolo Nucci
Journal:  Indian J Ophthalmol       Date:  2019-07       Impact factor: 1.848

2.  Contact lens rehabilitation following repaired corneal perforations.

Authors:  Jeewan S Titiyal; Rajesh Sinha; Namrata Sharma; V Sreenivas; Rasik B Vajpayee
Journal:  BMC Ophthalmol       Date:  2006-03-14       Impact factor: 2.209

3.  Estimation of the hybrid lens parameters through rigid gas permeable lens fitting.

Authors:  Mohammadali Hasani; Hassan Hashemi; Ebrahim Jafarzadehpur; Abbas Ali Yekta; Nooshin Dadbin; Mehdi Khabazkhoob
Journal:  J Curr Ophthalmol       Date:  2016-06-28

4.  A new technique for fitting of tricurve rigid gas-permeable contact lens in penetrating keratoplasty eyes using Scheimpflug imaging.

Authors:  Pratik Gogri; Faiza A Bhombal
Journal:  Indian J Ophthalmol       Date:  2020-06       Impact factor: 1.848

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.