Literature DB >> 10654898

Ultrasound-based stereotactic guidance of precision conformal external beam radiation therapy in clinically localized prostate cancer.

J Lattanzi1, S McNeeley, A Hanlon, T E Schultheiss, G E Hanks.   

Abstract

OBJECTIVES: Use of external beam radiation fields that conform to the shape of the target improves biochemical control in prostate cancer by facilitating dose escalation through increased sparing of normal tissue. By correcting potential organ motion and setup errors, ultrasound-directed stereotactic localization is a method that may improve the accuracy and effectiveness of current conformal technology. The purpose of this study was to quantify the precision of the transabdominal ultrasound-based approach using computed tomography (CT) as a standard.
METHODS: Thirty-five consecutive men participated in a prospective comparison of daily CT and ultrasound-guided localization at Fox Chase Cancer Center. Daily CT prostate localization was completed before the delivery of each final boost field. In the CT simulation suite, transabdominal ultrasound-based stereotactic localization was also performed. The main outcome measure was a three-dimensional comparison of prostate position as determined by CT versus ultrasound.
RESULTS: Sixty-nine daily CT and ultrasound prostate position shifts were recorded for 35 patients. The magnitude of difference between the CT and ultrasound localization ranged from 0 to 7.0 mm in the anterior/posterior, 0 to 6.4 mm in the lateral, and 0 to 6.7 mm in the superior/inferior dimension. The corresponding directed average disagreements were extremely small: anterior/posterior, -0.09 +/- 2.8 mm SD; lateral, -0.16 +/- 2.4 mm SD; and superior/inferior, -0.03 +/- 2.3 mm SD). Analysis of the paired CT-ultrasound shifts revealed a high correlation between the two modalities in all three dimensions (anterior/ posterior r = 0.88; lateral r = 0.91; and superior/inferior r = 0.87).
CONCLUSIONS: Ultrasound-directed stereotactic localization is safe and as accurate as CT scanning in targeting the prostate for conformal external beam radiation therapy. The application of this technology to current conformal techniques will allow the reduction of treatment margins in all dimensions. This should diminish treatment-related morbidity and facilitate further dose escalation, resulting in improved cancer control.

Entities:  

Mesh:

Year:  2000        PMID: 10654898     DOI: 10.1016/s0090-4295(99)00389-1

Source DB:  PubMed          Journal:  Urology        ISSN: 0090-4295            Impact factor:   2.649


  8 in total

1.  Monte Carlo investigations of megavoltage cone-beam CT using thick, segmented scintillating detectors for soft tissue visualization.

Authors:  Yi Wang; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Amit Sawant; Hong Du
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

2.  Post-radiotherapy prostate biopsies reveal heightened apex positivity relative to other prostate regions sampled.

Authors:  Kris T Huang; Radka Stoyanova; Gail Walker; Kiri Sandler; Matthew T Studenski; Nesrin Dogan; Tahseen Al-Saleem; Mark K Buyyounouski; Eric M Horwitz; Alan Pollack
Journal:  Radiother Oncol       Date:  2015-05-08       Impact factor: 6.280

3.  Image-guided intensity-modulated radiotherapy for pancreatic carcinoma.

Authors:  Martin Fuss; Adrian Wong; Clifton D Fuller; Bill J Salter; Cristina Fuss; Charles R Thomas
Journal:  Gastrointest Cancer Res       Date:  2007-01

4.  Tomotherapy as a tool in image-guided radiation therapy (IGRT): theoretical and technological aspects.

Authors:  S Yartsev; T Kron; J Van Dyk
Journal:  Biomed Imaging Interv J       Date:  2007-01-01

5.  Defining the radiation target on a daily basis.

Authors:  H J Dobbs
Journal:  Cancer Imaging       Date:  2006-04-25       Impact factor: 3.909

6.  Design and study of ultrasound-based automatic patient movement monitoring device for quantifying the intrafraction motion during teletherapy treatment.

Authors:  S Senthilkumar; R Vinothraj
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

7.  Clinical assessment and characterization of a dual tube kilovoltage X-ray localization system in the radiotherapy treatment room.

Authors:  Sung-Woo Lee; Jian-Yue Jin; Huaiqun Guan; Flavious Martin; Jae Ho Kim; Fang-Fang Yin
Journal:  J Appl Clin Med Phys       Date:  2008-01-13       Impact factor: 2.102

8.  Development of a treatment planning protocol for prostate treatments using intensity modulated radiotherapy.

Authors:  G A Ezzell; S E Schild; W W Wong
Journal:  J Appl Clin Med Phys       Date:  2001       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.