Analysis of risk factors associated with rupture of silicone gel breast implants.

L J Feng1, S B Amini.   

Abstract

Despite many recent studies on breast implant rupture, there is no general consensus on causation or incidence. Existing studies have not reported a multivariate analysis of risk factors associated with breast implant rupture. Most studies lack adequate sample size to study the effect of implant type, manufacturer, and other patient-related factors that might affect rupture. This study addresses all of these shortcomings. Patients undergoing implant removal by a single surgeon between 1990 and 1996 were examined for rupture and for 16 potential risk factors. The association between rupture and various factors was analyzed by univariate and multivariate analyses. A total of 842 patients underwent removal of 1619 implants. Increasing age of implant [p < 0.0001; adjusted odds ratio (OR), 1.20; 95% confidence interval (CI), 1.15 to 1.23], retroglandular location (p = 0.0002; OR, 1.93; CI, 1.37 to 2.71), Baker contracture grades III and IV (p = 0.005; OR, 1.52; CI, 1.14 to 2.03), and presence of local symptoms (p = 0.05; OR, 1.37; CI, 1.00 to 1.89) were associated with rupture. When different implant types were compared with smooth gel implants, after adjustment, double-lumen (p < 0.0001; OR, 0.33; CI, 0.22 to 0.50) and polyurethane-covered implants (p < 0.0002; OR, 0.33; CI, 0.20 to 0.57) had significantly lower rupture rates. When various manufacturers were compared with Dow Corning after adjusting for other factors, rupture rates were significantly lower for McGhan (p < 0.0001; OR, 0.41; CI, 0.26 to 0.65), whereas higher for Surgitek (p < 0.019; OR, 1.52; CI, 1.05 to 2.18). Significant risk factors for breast implant rupture were identified: older implants, retroglandular implant location, implant contracture, local symptoms, certain implant type, and certain manufacturer. Although the results of this study are based on a nonrandomized explant population from a single surgeon's practice, knowledge of these risk factors will permit better interpretation of future data on rupture. The knowledge will enable the medical community to better advise their breast implant population regarding durability and appropriate time for removal or replacement.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10654733     DOI: 10.1097/00006534-199909040-00009

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  9 in total

Review 1.  The Evolution of Breast Implants.

Authors:  Christodoulos Kaoutzanis; Julian Winocour; Jacob Unger; Allen Gabriel; G Patrick Maxwell
Journal:  Semin Plast Surg       Date:  2019-10-17       Impact factor: 2.314

2.  Assessment of Risk Factors for Rupture in Breast Reconstruction Patients with Macrotextured Breast Implants.

Authors:  Guido Paolini; Guido Firmani; Francesca Briganti; Mattia Macino; Simone Nigrelli; Michail Sorotos; Fabio Santanelli di Pompeo
Journal:  Aesthetic Plast Surg       Date:  2022-10-13       Impact factor: 2.708

Review 3.  An association of silicone-gel breast implant rupture and fibromyalgia.

Authors:  S Lori Brown; Hesha Jani Duggirala; Gene Pennello
Journal:  Curr Rheumatol Rep       Date:  2002-08       Impact factor: 4.592

4.  A retrospective analysis of ruptured breast implants.

Authors:  Woo Yeol Baek; Dae Hyun Lew; Dong Won Lee
Journal:  Arch Plast Surg       Date:  2014-11-03

Review 5.  History of breast implants: Back to the future.

Authors:  Fabio Santanelli di Pompeo; Guido Paolini; Guido Firmani; Michail Sorotos
Journal:  JPRAS Open       Date:  2022-03-11

6.  Axillary silicone lymphadenopathy presenting with a lump and altered sensation in the breast: a case report.

Authors:  Simon T Adams; Julie Cox; G Sam Rao
Journal:  J Med Case Rep       Date:  2009-03-10

7.  Poly Implant Prothèse silicone breast implants: implant dynamics and capsular contracture.

Authors:  Y Bachour; Z C M Heinze; T S Dormaar; W G van Selms; M J P F Ritt; F B Niessen
Journal:  Eur J Plast Surg       Date:  2018-06-01

8.  Mechanical irritation by protruding bone: A possible cause of breast implant rupture.

Authors:  Matthias Michael Aitzetmüller; David Johannes Haslhofer; Raphael Wenny; Manfred Schmidt; Dominik Duscher; Georg Michael Huemer
Journal:  Arch Plast Surg       Date:  2018-09-15

9.  Diagnostic value of a spiral breast computed tomography system equipped with photon counting detector technology in patients with implants: An observational study of our initial experiences.

Authors:  Lisa Ruby; Sojin Shim; Nicole Berger; Magda Marcon; Thomas Frauenfelder; Andreas Boss
Journal:  Medicine (Baltimore)       Date:  2020-07-24       Impact factor: 1.817