Literature DB >> 10653035

In vivo moment arm determination using B-mode ultrasonography.

M Ito1, H Akima, T Fukunaga.   

Abstract

The tendon excursion of the tibialis anterior (TA) muscle was measured in vivo using B-mode ultrasonography in seven subjects under three force levels (0, 30 and 60% maximal voluntary contraction, MVC). For each force level, the TA moment arm (m) was determined by calculating the derivative of the tendon excursion relative to the ankle angle (a). A dynamometer controlled the ankle angle while force levels were monitored. The parametric model proposed by Miller and Dennis (1996), m = R sin(a + delta), where R is the largest moment arm and delta represents the offset angle of R from 90 degrees, was used in a least-squares fit of the relationship between moment arm and ankle angle. The R values at 0% MVC were significantly smaller than those at 30 and 60% MVC. The values of calculated moment arm at 0% MVC were not considered adequate estimates of the TA moment arm because of the possible confounding effect of the slackness of the relaxed muscle-tendon unit in more dorsiflexed positions. The moment arm values at 30 and 60% MVC were believed to provide reliable estimates of those of TA since the application of tension probably reduced the effects of the slackness of the muscle-tendon unit and tendon elongation on tendon excursion measurement at these force levels. Since the ultrasonographic technique is an in vivo application of the tendon excursion technique and therefore takes the functional meaning into consideration, it can yield more significant moment arms than other in vivo or cadaver techniques.

Entities:  

Mesh:

Year:  2000        PMID: 10653035     DOI: 10.1016/s0021-9290(99)00154-2

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  19 in total

Review 1.  Imaging-based estimates of moment arm length in intact human muscle-tendons.

Authors:  Constantinos N Maganaris
Journal:  Eur J Appl Physiol       Date:  2003-12-18       Impact factor: 3.078

2.  Changes in tendon stiffness and running economy in highly trained distance runners.

Authors:  Jared R Fletcher; Shane P Esau; Brian R MacIntosh
Journal:  Eur J Appl Physiol       Date:  2010-08-04       Impact factor: 3.078

3.  Maximum voluntary joint torque as a function of joint angle and angular velocity: model development and application to the lower limb.

Authors:  Dennis E Anderson; Michael L Madigan; Maury A Nussbaum
Journal:  J Biomech       Date:  2007-05-07       Impact factor: 2.712

4.  Can muscle shortening alone, explain the energy cost of muscle contraction in vivo?

Authors:  Jared R Fletcher; Erik M Groves; Ted R Pfister; Brian R Macintosh
Journal:  Eur J Appl Physiol       Date:  2013-05-28       Impact factor: 3.078

5.  Rectus femoris knee muscle moment arms measured in vivo during dynamic motion with real-time magnetic resonance imaging.

Authors:  Niccolo M Fiorentino; Jonathan S Lin; Kathryn B Ridder; Michael A Guttman; Elliot R McVeigh; Silvia S Blemker
Journal:  J Biomech Eng       Date:  2013-04       Impact factor: 2.097

6.  Achilles tendon strain energy in distance running: consider the muscle energy cost.

Authors:  Jared R Fletcher; Brian R MacIntosh
Journal:  J Appl Physiol (1985)       Date:  2014-11-13

Review 7.  MRI of weight bearing and movement.

Authors:  L M Shapiro; G E Gold
Journal:  Osteoarthritis Cartilage       Date:  2011-11-17       Impact factor: 6.576

8.  Dependence of Muscle Moment Arms on In Vivo Three-Dimensional Kinematics of the Knee.

Authors:  Alessandro Navacchia; Vasiliki Kefala; Kevin B Shelburne
Journal:  Ann Biomed Eng       Date:  2016-09-12       Impact factor: 3.934

9.  Coactivation pattern in human quadriceps during isokinetic knee-extension by muscle functional MRI.

Authors:  Hiroshi Akima; Hideyuki Takahashi; Shin-ya Kuno; Shigeru Katsuta
Journal:  Eur J Appl Physiol       Date:  2003-10-09       Impact factor: 3.078

10.  Measurement of tendon strain during muscle twitch contractions using ultrasound elastography.

Authors:  Joe Farron; Tomy Varghese; Darryl G Thelen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-01       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.