Literature DB >> 10651793

Volumetric measurements of peripheral oedema in clinical conditions.

F Brijker1, Y F Heijdra, F J Van Den Elshout, F H Bosch, H T Folgering.   

Abstract

Water-displacement volumetry can be used for quantifying the volume of the leg. However, not much is known about its application in patients with peripheral oedema of cardiopulmonary origin. We measured the reproducibility of a water-displacement apparatus with a solid object and in ten non-oedematous clinical patients (group A). The day-to-day variability of the leg volume was assessed in the same group. The diurnal variability was assessed in ten patients with persisting peripheral oedema (group B). The effect of treatment on the severity of peripheral oedema was evaluated in another nine patients with peripheral oedema, who were in need of diuretic treatment (group C). Volumetric results were compared to the ankle circumference method and the body weight method. The coefficient of variation was 0.16% in the fixed object and 0.47% in group A. The day-to-day variability was 1.52% after 1 day and 1.76% after a mean interval of 4.8 days. In group B, leg volume and circumference increased during the day (5.9%, P<0.001, and 2.4%, P<0.01, respectively), while body weight remained unchanged. In group C, leg volume, circumference and body weight decreased significantly after treatment (13.1%, P<0.01, 7.1%, P<0.05, and 5.9%, P<0.05). The correlation between the changes in volume and body weight was poor (r=0.37, P=0.33). In conclusion, (1) water-displacement volumetry is highly reproducible, (2) a diurnal variability of peripheral oedema was found, and (3) volumetry is a suitable tool for monitoring peripheral oedema, while the body weight method appears to be less accurate.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10651793     DOI: 10.1046/j.1365-2281.2000.00224.x

Source DB:  PubMed          Journal:  Clin Physiol        ISSN: 0144-5979


  9 in total

1.  Use of an inelastic bandage as an adaptation of the lymphatic drainage technique in lower limbs.

Authors:  Guilherme Fregonezi; Vanessa Resqueti; Socorro Ferreira; Ana Paula Lima
Journal:  BMJ Case Rep       Date:  2009-04-14

Review 2.  Water displacement leg volumetry in clinical studies--a discussion of error sources.

Authors:  Eberhard Rabe; Markus Stücker; Bertram Ottillinger
Journal:  BMC Med Res Methodol       Date:  2010-01-13       Impact factor: 4.615

3.  Kinesio taping and the circulation and endurance ratio of the gastrocnemius muscle.

Authors:  Hannah L Stedge; Ryan M Kroskie; Carrie L Docherty
Journal:  J Athl Train       Date:  2012 Nov-Dec       Impact factor: 2.860

4.  Ankle manual therapy for individuals with post-acute ankle sprains: description of a randomized, placebo-controlled clinical trial.

Authors:  Todd E Davenport; Kornelia Kulig; Beth E Fisher
Journal:  BMC Complement Altern Med       Date:  2010-10-19       Impact factor: 3.659

5.  Reproducibility and day time bias correction of optoelectronic leg volumetry: a prospective cohort study.

Authors:  Rolf P Engelberger; Claudia Blazek; Felix Amsler; Hong H Keo; Frédéric Baumann; Werner Blättler; Iris Baumgartner; Torsten Willenberg
Journal:  BMC Med Res Methodol       Date:  2011-10-05       Impact factor: 4.615

6.  Evaluation of the Accuracy of a Video and AI Solution to Measure Lower Leg and Foot Volume.

Authors:  Oriane Chausiaux; Gareth Williams; Michał Nieznański; Adem Bagdu; Philip Downer; Melanie Keyser; Shamus Husheer
Journal:  Med Devices (Auckl)       Date:  2021-04-13

7.  Identification of potential neuromotor mechanisms of manual therapy in patients with musculoskeletal disablement: rationale and description of a clinical trial.

Authors:  Beth E Fisher; Todd E Davenport; Kornelia Kulig; Allan D Wu
Journal:  BMC Neurol       Date:  2009-05-21       Impact factor: 2.474

8.  Metabolic stress-like condition can be induced by prolonged strenuous exercise in athletes.

Authors:  Stefan Branth; Leif Hambraeus; Karin Piehl-Aulin; Birgitta Essén-Gustavsson; Torbjörn Akerfeldt; Roger Olsson; Mats Stridsberg; Gunnar Ronquist
Journal:  Ups J Med Sci       Date:  2009       Impact factor: 2.384

9.  Limb volume measurements: comparison of accuracy and decisive parameters of the most used present methods.

Authors:  Adam Chromy; Ludek Zalud; Petr Dobsak; Igor Suskevic; Veronika Mrkvicova
Journal:  Springerplus       Date:  2015-11-19
  9 in total