Literature DB >> 10647983

Radio frequency radiation of millimeter wave length: potential occupational safety issues relating to surface heating.

K L Ryan1, J A D'Andrea, J R Jauchem, P A Mason.   

Abstract

Currently, technology is being developed that makes use of the millimeter wave (MMW) range (30-300 GHz) of the radio frequency region of the electromagnetic spectrum. As more and more systems come on line and are used in everyday applications, the possibility of inadvertent exposure of personnel to MMWs increases. To date, there has been no published discussion regarding the health effects of MMWs; this review attempts to fill that void. Because of the shallow depth of penetration, the energy and, therefore, heat associated with MMWs will be deposited within the first 1-2 mm of human skin. MMWs have been used in states of the former Soviet Union to provide therapeutic benefit in a number of diverse disease states, including skin disorders, gastric ulcers, heart disease and cancer. Conversely, the possibility exists that hazards might be associated with accidental overexposure to MMWs. This review attempts to critically analyze the likelihood of such acute effects as burn and eye damage, as well as potential long-term effects, including cancer.

Entities:  

Mesh:

Year:  2000        PMID: 10647983     DOI: 10.1097/00004032-200002000-00006

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  7 in total

1.  Temperature and burn injury prediction of human skin exposed to microwaves: a model analysis.

Authors:  Sukru Ozen; Selcuk Helhel; Suleyman Bilgin
Journal:  Radiat Environ Biophys       Date:  2011-04-30       Impact factor: 1.925

2.  Safe for Generations to Come.

Authors:  Ting Wu; Theodore S Rappaport; Christopher M Collins
Journal:  IEEE Microw Mag       Date:  2015-02-05       Impact factor: 2.714

3.  Low-intensity electromagnetic millimeter waves for pain therapy.

Authors:  Taras I Usichenko; Hardy Edinger; Vasyl V Gizhko; Christian Lehmann; Michael Wendt; Frank Feyerherd
Journal:  Evid Based Complement Alternat Med       Date:  2006-04-24       Impact factor: 2.629

4.  Potential of Wake-Up Radio-Based MAC Protocols for Implantable Body Sensor Networks (IBSN)-A Survey.

Authors:  Vignesh Raja Karuppiah Ramachandran; Eyuel D Ayele; Nirvana Meratnia; Paul J M Havinga
Journal:  Sensors (Basel)       Date:  2016-11-29       Impact factor: 3.576

Review 5.  Review on Acoustic Droplet Vaporization in Ultrasound Diagnostics and Therapeutics.

Authors:  Ksenia Loskutova; Dmitry Grishenkov; Morteza Ghorbani
Journal:  Biomed Res Int       Date:  2019-07-14       Impact factor: 3.411

Review 6.  PLGA-Based Drug Delivery Systems for Remotely Triggered Cancer Therapeutic and Diagnostic Applications.

Authors:  Xue Shen; Tingting Li; Xiaoxue Xie; Yi Feng; Zhongyuan Chen; Hong Yang; Chunhui Wu; Shengqi Deng; Yiyao Liu
Journal:  Front Bioeng Biotechnol       Date:  2020-05-05

7.  The Impact of Base Cell Size Setup on the Finite Difference Time Domain Computational Simulation of Human Cornea Exposed to Millimeter Wave Radiation at Frequencies above 30 GHz.

Authors:  Negin Foroughimehr; Zoltan Vilagosh; Ali Yavari; Andrew Wood
Journal:  Sensors (Basel)       Date:  2022-08-08       Impact factor: 3.847

  7 in total