Literature DB >> 10646788

Patch incorporation in diaphragmatic hernia.

C P Kimber1, M P Dunkley, G Haddock, L Robertson, F A Carey, A Cuschieri.   

Abstract

BACKGROUND/
PURPOSE: Biomaterial insertion often is required for closure of congenital diaphragmatic hernia (CDH). The optimal biomaterial remains uncertain. This study was designed to compare a commonly used patch (polytetrafluoroethylene) with a recently available fabric, fluorinated polyester. The aim of this study was to determine the clinical performance, histological tissue-polymer interaction, bacterial adhesion, and shrinkage rates of biomaterial inserted endoscopically into a CDH lamb model.
METHODS: Polytetrafluoro-ethylene (PTFE) and fluorinated polyester (FP) were randomised for laparoscopic patch insertion into 12 lambs. All lambs (age <4 weeks) underwent 3-port laparoscopy, surgical creation of diaphragmatic hernia, and sutured patch placement. Two PTFE and 2 FP lambs were killed at 1-, 3-, and 6-month intervals postoperatively. Postmortem examination histopathology, electron microscopy, and specific bacterial broth immersion (Escherichia coil, Staphylococcus aurens, and epidermidis) were performed.
RESULTS: All 12 lambs completed the study with intact patches that were fully peritonised. One abdominal adhesion was noted in a FP lamb at 6 months. FP was comparatively easier to insert, manipulate, and suture endoscopically. Histopathology findings showed that PTFE patches created a strong peripheral foreign body reaction with dystrophic calcification, whereas FP was well incorporated with intrapatch fibroblastic activity and neovascularsation. No significant difference in resistance to bacterial adhesion of relevant organisms was noted between the materials. Graft shrinkage for FP was 7% in one direction only, evident by 3 months.
CONCLUSIONS: Fluorinated polyester has advantages in this laparoscopic lamb model. It shows rapid and sustained incorporation with intrapatch neovascularisation when compared with polytetrafluoro-ethylene's significant foreign body reaction. It was preferred for its endoscopic handling and suturing properties. The laparoscopic techniques used may contribute to the general lack of adhesions, and insufficient data are available to comment on the comparative effect of the materials on adhesion formation. No difference was demonstrated in resistance to bacterial adherence in the harvested materials.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10646788     DOI: 10.1016/s0022-3468(00)80027-5

Source DB:  PubMed          Journal:  J Pediatr Surg        ISSN: 0022-3468            Impact factor:   2.545


  5 in total

1.  The susceptibility of prosthetic biomaterials to infection.

Authors:  A M Carbonell; B D Matthews; D Dréau; M Foster; C E Austin; K W Kercher; R F Sing; B T Heniford
Journal:  Surg Endosc       Date:  2004-12-09       Impact factor: 4.584

2.  Evaluation of diaphragmatic hernia repair using PLGA mesh-collagen sponge hybrid scaffold: an experimental study in a rat model.

Authors:  Yasuhisa Urita; Hiroaki Komuro; Guoping Chen; Miki Shinya; Ryoko Saihara; Michio Kaneko
Journal:  Pediatr Surg Int       Date:  2008-07-31       Impact factor: 1.827

3.  Heparinized collagen scaffolds with and without growth factors for the repair of diaphragmatic hernia: construction and in vivo evaluation.

Authors:  Katrien M Brouwer; René M Wijnen; Daphne Reijnen; Theo G Hafmans; Willeke F Daamen; Toin H van Kuppevelt
Journal:  Organogenesis       Date:  2013-07-18       Impact factor: 2.500

4.  Evaluation of DualMesh for repair of large hiatus hernia in a porcine model.

Authors:  G S Smith; E J Hazebroek; R Eckstein; H Berry; W M Smith; J R Isaacson; G L Falk; C J Martin
Journal:  Surg Endosc       Date:  2007-11-14       Impact factor: 4.584

5.  Incorporation of Integra in tissue defects: a pilot study in the rat model.

Authors:  Manasvi Upadhyaya; J E Orford; Nicholas Smith; Andrew Barker; I Gollow
Journal:  Pediatr Surg Int       Date:  2007-05-08       Impact factor: 2.003

  5 in total