The usefulness of iodine-123 whole-body scans in evaluating thyroid carcinoma and metastases.

W Yaakob1, L Gordon, K M Spicer, S J Nitke.   

Abstract

OBJECTIVE: It is recognized that diagnostic doses of (131)I larger than 3 mCi will cause some cell injury to the tissue in which it concentrates and reduce subsequent uptake of (131)I administered therapeutically. Iodine-123 has been suggested as an alternate radiopharmaceutical to perform whole-body scans since its primary emissions are photons with minimal particulate radiation and it does not cause thyroid stunning and cell injury. The purpose of this study was to assess the effectiveness of (123)I for whole-body scans.
METHODS: We examined 12 patients who had (123)I whole-body scans for known papillary/follicular thyroid cancer and 1 patient with Hurthle cell carcinoma, all with suspected metastases. All patients had undergone neck surgery and were given 0.81-0 mCi (123)I. Twenty-four hours later a whole-body image and static views of relevant areas were obtained. If abnormal uptake was noted, patients were treated with large doses of (131)I and then had whole-body (131)I scans 7-10 d post-therapy. These images were compared to (123)I whole-body scans.
RESULTS: All 13 patients had abnormal (123)I scans and were treated with therapeutic doses of (123)I, followed by whole-body scans 7-10 d later. In 11 patients the activity seen on the 123I scans correlated well with that seen on (131)I scans. In 1 patient, additional lesions were noted on the (131)I images. In another patient, neck activity was seen on the (123)I scan but not on the subsequent (131)I post-therapy scan. The (123)I activity was felt to represent esophageal lumen activity.
CONCLUSION: We found (123)1 effective in demonstrating residual thyroid tissue, thyroid carcinoma and metastases, and recommend its use for whole-body iodine scans since it does not cause thyroid stunning.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10646545

Source DB:  PubMed          Journal:  J Nucl Med Technol        ISSN: 0091-4916


  6 in total

1.  Effect of distance between decaying (125)I and DNA on Auger-electron induced double-strand break yield.

Authors:  Pichumani Balagurumoorthy; Xiang Xu; Ketai Wang; S James Adelstein; Amin I Kassis
Journal:  Int J Radiat Biol       Date:  2012-07-24       Impact factor: 2.694

2.  DNA double-strand breaks induced by decay of (123)I-labeled Hoechst 33342: role of DNA topology.

Authors:  Pichumani Balagurumoorthy; Ketai Wang; S James Adelstein; Amin I Kassis
Journal:  Int J Radiat Biol       Date:  2008-12       Impact factor: 2.694

3.  Iodine-123 as a diagnostic imaging agent in differentiated thyroid carcinoma: a comparison with iodine-131 post-treatment scanning and serum thyroglobulin measurement.

Authors:  Muammer Urhan; Simin Dadparvar; Ayse Mavi; Mohamed Houseni; Wichana Chamroonrat; Abass Alavi; Susan J Mandel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-01-26       Impact factor: 10.057

4.  Rate of thyroglossal duct remnant visualization after total thyroidectomy for differentiated thyroid carcinoma and its impact on clinical outcome of radioactive iodine (I-131) ablation.

Authors:  Mohamed Hosny Mohamed Sayed; Hussein Rabie Saleh Farghaly; Fahd Ahmad Fadl
Journal:  Indian J Nucl Med       Date:  2015 Apr-Jun

5.  To treat or not to treat: the role of adjuvant radioiodine therapy in thyroid cancer patients.

Authors:  Marilee Carballo; Roderick M Quiros
Journal:  J Oncol       Date:  2012-11-01       Impact factor: 4.375

6.  Current role of radionuclide imaging in differentiated thyroid cancer.

Authors:  K T Wong; Frankie P T Choi; Yolanda Y P Lee; Anil T Ahuja
Journal:  Cancer Imaging       Date:  2008-09-10       Impact factor: 3.909