Literature DB >> 10646279

A multichannel continuously selectable multifrequency electrical impedance spectroscopy measurement system.

A Hartov1, R A Mazzarese, F R Reiss, T E Kerner, K S Osterman, D B Williams, K D Paulsen.   

Abstract

There is increasing evidence that alterations in the electrical property spectrum of tissues below 10 MHz is diagnostic for tissue pathology and/or pathophysiology. Yet, the complexity associated with constructing a high-fidelity multichannel, multifrequency data acquisition instrument has limited widespread development of spectroscopic electrical impedance imaging concepts. To contribute to the relatively sparse experience with multichannel spectroscopy systems this paper reports on the design, realization and evaluation of a prototype 32-channel instrument. The salient features of the system include a continuously selectable driving frequency up to 1 MHz, either voltage or current source modes of operation and simultaneous measurement of both voltage and current on each channel in either of these driving configurations. Comparisons of performance with recently reported fixed-frequency systems is favorable. Volts dc (VDC) signal-to-noise ratios of 75-80 dB are achieved and the noise floor for ac signals is near 100 dB below the signal strength of interest at 10 kHz and 60 dB down at 1 MHz. The added benefit of being able to record multispectral information on source and sense signal amplitudes and phases has also been realized. Phase-sensitive detection schemes and multiperiod undersampling techniques have been deployed to ensure measurement fidelity over the full bandwidth of system operation.

Mesh:

Year:  2000        PMID: 10646279     DOI: 10.1109/10.817619

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  6 in total

1.  An Algorithm for Applying Multiple Currents Using Voltage Sources in Electrical Impedance Tomography.

Authors:  Myoung H Choi; Tzu-Jen Kao; David Isaacson; Gary J Saulnier; Jonathan C Newell
Journal:  Int J Control Autom Syst       Date:  2008-01-01       Impact factor: 3.314

2.  A high-precision voltage source for EIT.

Authors:  Gary J Saulnier; Alexander S Ross; Ning Liu
Journal:  Physiol Meas       Date:  2006-04-24       Impact factor: 2.833

3.  A reconstruction algorithm for breast cancer imaging with electrical impedance tomography in mammography geometry.

Authors:  Myoung Hwan Choi; Tzu-Jen Kao; David Isaacson; Gary J Saulnier; Jonathan C Newell
Journal:  IEEE Trans Biomed Eng       Date:  2007-04       Impact factor: 4.538

4.  Regional admittivity spectra with tomosynthesis images for breast cancer detection: preliminary patient study.

Authors:  Tzu-Jen Kao; Gregory Boverman; Bong Seok Kim; David Isaacson; Gary J Saulnier; Jonathan C Newell; Myoung H Choi; Richard H Moore; Daniel B Kopans
Journal:  IEEE Trans Med Imaging       Date:  2008-12       Impact factor: 10.048

5.  Toward Non-Invasive and Automatic Intravenous Infiltration Detection: Evaluation of Bioimpedance and Skin Strain in a Pig Model.

Authors:  A Ozan Bicen; Leanne L West; Liliana Cesar; Omer T Inan
Journal:  IEEE J Transl Eng Health Med       Date:  2018-04-03       Impact factor: 3.316

6.  Wideband Fully-Programmable Dual-Mode CMOS Analogue Front-End for Electrical Impedance Spectroscopy.

Authors:  Virgilio Valente; Andreas Demosthenous
Journal:  Sensors (Basel)       Date:  2016-07-25       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.