Dependence of apparent resistance of four-electrode probes on insertion depth.

J Z Tsai1, H Cao, S Tungjitkusolmun, E J Woo, V R Vorperian, J G Webster.   

Abstract

The apparent resistance of a finite-thickness layer measured with a four-electrode plunge probe depends on the electrode insertion depth, electrode spacing, and layer thickness, as well as the resistivity ratio of an underlying layer. A physical model consisting of air, a saline solution layer, and an agar layer simulates the real situation of resistivity measurement. The saline layer represents the finite-thickness layer whose resistivity is to be measured by a plunge electrode probe, and the agar layer represents an underlying perturbing layer. A micropositioner controls the insertion depth of the four electrodes into the saline solution. With the apparent resistance measured on a semi-infinite-thickness layer of saline solution as standard, measurement results show decreasing apparent resistance and increasing error with increasing electrode insertion depth. This information is important for correct measurement of myocardial resistivity in vivo and in vitro.

Entities:  

Mesh:

Year:  2000        PMID: 10646278     DOI: 10.1109/10.817618

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  10 in total

1.  Changes in electrical resistivity of swine liver after occlusion and postmortem.

Authors:  D Haemmerich; R Ozkan; S Tungjitkusolmun; J Z Tsai; D M Mahvi; S T Staelin; J G Webster
Journal:  Med Biol Eng Comput       Date:  2002-01       Impact factor: 2.602

2.  Design of Bioimpedance Spectroscopy Instrument With Compensation Techniques for Soft Tissue Characterization.

Authors:  Robert E Dodde; Grant H Kruger; Albert J Shih
Journal:  J Med Device       Date:  2015-06       Impact factor: 0.582

3.  RF ablation at low frequencies for targeted tumor heating: in vitro and computational modeling results.

Authors:  Dieter Haemmerich; David J Schutt
Journal:  IEEE Trans Biomed Eng       Date:  2010-10-07       Impact factor: 4.538

4.  Electrical conductivity measurement of excised human metastatic liver tumours before and after thermal ablation.

Authors:  Dieter Haemmerich; David J Schutt; Andrew W Wright; John G Webster; David M Mahvi
Journal:  Physiol Meas       Date:  2009-04-06       Impact factor: 2.833

5.  An impedance sensor to monitor and control cerebral ventricular volume.

Authors:  Andreas Linninger; Sukhraaj Basati; Robert Dawe; Richard Penn
Journal:  Med Eng Phys       Date:  2009-05-05       Impact factor: 2.242

6.  Separation of Subcutaneous Fat From Muscle in Surface Electrical Impedance Myography Measurements Using Model Component Analysis.

Authors:  Hyeuknam Kwon; Wasim Q Malik; Seward B Rutkove; Benjamin Sanchez
Journal:  IEEE Trans Biomed Eng       Date:  2018-05-23       Impact factor: 4.538

7.  Electrochemical safety limits for clinical stimulation investigated using depth and strip electrodes in the pig brain.

Authors:  Ritwik Vatsyayan; Daniel Cleary; Joel R Martin; Eric Halgren; Shadi A Dayeh
Journal:  J Neural Eng       Date:  2021-06-04       Impact factor: 5.043

8.  Electrical impedance along connective tissue planes associated with acupuncture meridians.

Authors:  Andrew C Ahn; Junru Wu; Gary J Badger; Richard Hammerschlag; Helene M Langevin
Journal:  BMC Complement Altern Med       Date:  2005-05-09       Impact factor: 3.659

9.  Do changes in electrical skin resistance of acupuncture points reflect menstrual pain? A comparative study in healthy volunteers and primary dysmenorrhea patients.

Authors:  Yan-Fen She; Liang-Xiao Ma; Cong-Hui Qi; Yan-Xia Wang; Ling Tang; Chun-Hua Li; Hong-Wen Yuan; Yu-Qi Liu; Jia-Shan Song; Jiang Zhu
Journal:  Evid Based Complement Alternat Med       Date:  2014-04-27       Impact factor: 2.629

10.  Techniques for epicardial mapping and ablation with a miniature robotic walker.

Authors:  Dwight A Meglan; Wener Lv; Richard J Cohen; Cameron N Riviere
Journal:  Robot Surg       Date:  2017-03-23
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.