Literature DB >> 10644488

Transrectal ultrasound assessment of murine aorta and iliac arteries.

A C Chiou1, B Chiu, W F Oppat, J S Matsumura, R L Chisholm, W H Pearce.   

Abstract

Recent research in arterial aneurysm formation has focused on animal model development. Mice are an ideal experimental organism due to their short life cycle, prolific progeny, and extensively studied genome. Most experiments require the sacrifice of the mice to observe and assess any morphological changes. Noninvasive or minimally invasive imaging is limited due to the relatively small size of the structures. The development of such a technique, therefore, is especially useful for allowing repeated measurement without sacrificing the mice. We introduce a novel technique of imaging and measuring the aorta, the aorta/inferior vena cava complex, and the right and the left common iliac artery/vein complex by the use of an intravascular ultrasound catheter. The catheter is inserted through the anus and rectum and into the sigmoid and left colon, where the aorta can be observed to fluctuate at approximately 500 beats/min. The aortic bifurcation can also be observed. The diameters of the aorta and the inferior vena cava were measured first with the transrectal ultrasound technique and then with direct visualization upon laparotomy for 10 mice. This revealed a percentage error between 13.7 and 14.2% for this novel technique. Fifteen more sets of vessel measurements were also made with 8 male and 7 female mice. The results demonstrated a correlation between vessel size and body weight in male but not female mice and suggested an intersex difference in vessel growth rate. We conclude that transrectal ultrasound is a useful tool in imaging and measuring the murine aorta and its bifurcation. Copyright 2000 Academic Press.

Entities:  

Mesh:

Year:  2000        PMID: 10644488     DOI: 10.1006/jsre.1999.5790

Source DB:  PubMed          Journal:  J Surg Res        ISSN: 0022-4804            Impact factor:   2.192


  2 in total

1.  Murine ultrasound imaging for circumferential strain analyses in the angiotensin II abdominal aortic aneurysm model.

Authors:  John T Favreau; Binh T Nguyen; Ian Gao; Peng Yu; Ming Tao; Jacob Schneiderman; Glenn R Gaudette; C Keith Ozaki
Journal:  J Vasc Surg       Date:  2012-04-14       Impact factor: 4.268

2.  In vivo quantification of murine aortic cyclic strain, motion, and curvature: implications for abdominal aortic aneurysm growth.

Authors:  Craig J Goergen; Kyla N Barr; Diem T Huynh; Jeffrey R Eastham-Anderson; Gilwoo Choi; Maj Hedehus; Ronald L Dalman; Andrew J Connolly; Charles A Taylor; Philip S Tsao; Joan M Greve
Journal:  J Magn Reson Imaging       Date:  2010-10       Impact factor: 4.813

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.