Literature DB >> 10643749

Accuracy of human circadian entrainment under natural light conditions: model simulations.

D G Beersma1, K Spoelstra, S Daan.   

Abstract

The patterns of light intensity to which humans expose their circadian pacemakers in daily life are very irregular and vary greatly from day to day. The circadian pacemaker can adjust to such irregular exposure patterns by daily phase shifts, such as summarized in a phase response curve. It is demonstrated in this paper on the basis of computer simulations applying actually recorded human light exposure patterns that the pacemaker can substantially improve its accuracy by an additional response to light: For that purpose, it should additionally change its angular velocity (and consequently its period tau) in response to light. Reductions of tau in response to light in the morning and increases of tau in response to light in the evening can lead to an increase in entrained pacemaker accuracy with about 25%. Circadian pacemakers have evolved as accurate internal representations of external time, and investigated diurnal mammals all seem to respond to light by changing the period of their circadian pacemaker (in addition to shifting phase). The authors suggest that also human circadian systems take advantage of this possibility and that their pacemakers respond to light by shifting phase and changing period. As a consequence of this postulated mechanism, the simulations demonstrate that the period of the pacemaker under normally entrained conditions is 24 h. The maximum accuracy corresponds to a day-to-day standard deviation of the time of phase 0 of circa 15 min. This is considerably more accurate than the light signal humans usually perceive.

Entities:  

Mesh:

Year:  1999        PMID: 10643749     DOI: 10.1177/074873099129000858

Source DB:  PubMed          Journal:  J Biol Rhythms        ISSN: 0748-7304            Impact factor:   3.182


  2 in total

1.  Intrinsic near-24-h pacemaker period determines limits of circadian entrainment to a weak synchronizer in humans.

Authors:  K P Wright; R J Hughes; R E Kronauer; D J Dijk; C A Czeisler
Journal:  Proc Natl Acad Sci U S A       Date:  2001-11-20       Impact factor: 11.205

2.  Modeling natural photic entrainment in a subterranean rodent (Ctenomys aff. knighti), the Tuco-Tuco.

Authors:  Danilo E F L Flôres; Barbara M Tomotani; Patricia Tachinardi; Gisele A Oda; Veronica S Valentinuzzi
Journal:  PLoS One       Date:  2013-07-10       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.