Literature DB >> 10642132

Influence of the pacing rate on the atrioventricular conduction time during aerobic and anaerobic exercise: basic concepts for a dromotropically controlled rate responsive pacemaker.

M Meine1, M Hexamer, J Werner, C W Israel, A Mügge, B Lemke, J Barmeyer.   

Abstract

The dromotropic pacemaker concept needs a rate responsive algorithm in which the pacing rate is controlled by the atrioventricular conduction time (AVCT). To develop basic concepts for such a rate responsive algorithm, the influence of the pacing rate on the AVCT was investigated. Seven patients (62 +/- 7.8 years) with sick sinus syndrome and intact atrioventricular conduction underwent two cardiopulmonary exercise tests (CPX) on a treadmill. According to the determination of the anaerobic threshold (AT) and the patients maximum capacity in the first incremental CPX the work rate for two exercise levels below and above the AT were chosen for the second constant workload CPX. The calculation of the optimal pacing rate (HRopt) was based on the oxygen uptake (VO2) during exercise after reaching steady-state conditions. According to the increase of the VO2 from 14.8 +/- 2.3 mL/min per kilogram during aerobic work (38.3 +/- 16.0 W) to 19.4 +/- 4.7 mL/min per kilogram during anaerobic work (80.6 +/- 32.3 W), the HRopt was calculated to be 98.6 +/- 6.9 beats/min and 116.4 +/- 4.7 beats/min. Starting from HRopt, the pacing rate was increased (overpacing) and decreased (underpacing) by about 5 beats/min every minute. At optimal pacing rate the AVCT decreased significantly from 233.0 +/- 30.5 ms during aerobic work and to 226.4 +/- 27.3 ms during anaerobic work (P < 0.05). Whereas overpacing induced a significant prolongation of the AVCT during aerobic work (4.17 +/- 1.78 ms per 10 beats/min) and anaerobic work (3.84 +/- 1.60 ms per 10 beats/min), underpacing yielded a significant shortening of the AVCT by about 4.49 +/- 2.64 ms per 10 beats/min during aerobic work and 4.75 +/- 1.87 ms per 10 beats/min during anaerobic work (P < 0.01). The slopes of the regression lines of the relationship between AVCT and pacing rate were not significantly. different. Based on the reciprocal relationship of heart rate (HR) and AVCT, basic concepts may be established for a dromotropic rate responsive algorithm.

Entities:  

Mesh:

Year:  1999        PMID: 10642132     DOI: 10.1111/j.1540-8159.1999.tb00411.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  2 in total

1.  Rate-responsive pacing using the atrio-ventricular conduction time: design and test of a new algorithm.

Authors:  M Hexamer; C Drewes; M Meine; A Kloppe; J Weckmüller; A Mügge; J Werner
Journal:  Med Biol Eng Comput       Date:  2004-09       Impact factor: 2.602

2.  [Not Available].

Authors:  M Meine; M Hexamer; B Lemke; J Werner
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2000-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.