Surface plasmon resonance (SPR) analysis of coagulation in whole blood with application in prothrombin time assay.

K M Hansson1, T P Vikinge, M Rånby, P Tengvall, I Lundström, K Johansen, T L Lindahl.   

Abstract

It is previously shown that surface plasmon resonance (SPR) can be used to study blood plasma coagulation. This work explores the use of this technique for the analysis of tissue factor induced coagulation, i.e. prothrombin time (PT) analysis, of whole blood and plasma. The reference method was nephelometry. The prothrombin time analysis by SPR was performed by mixing two volumes of blood/plasma, one volume of thromboplastin, and one volume of CaCl2 solution directly on a sensor surface. The measurements show good agreement between nephelometry and SPR plasma analysis and also between SPR plasma and whole blood analysis. The effect of anticoagulant treatment on the clotting times was significant both quantitatively and qualitatively. The impact on the SPR signal of different physiological events in the coagulation process is discussed, and tentative interpretations of the sensorgram features are given. The major advantage of the SPR method compared to nephelometry is the possibility to perform analysis on whole blood instead of plasma. In conclusion, SPR is a promising method for whole blood coagulation analysis.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10641287     DOI: 10.1016/s0956-5663(99)00050-0

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

1.  Real-Time Monitoring of Platelet Activation Using Quartz Thickness-Shear Mode Resonator Sensors.

Authors:  Huiyan Wu; Guangyi Zhao; Hongfei Zu; James H-C Wang; Qing-Ming Wang
Journal:  Biophys J       Date:  2016-02-02       Impact factor: 4.033

2.  Whole blood optical biosensor.

Authors:  Lisa M Bonanno; Lisa A DeLouise
Journal:  Biosens Bioelectron       Date:  2007-07-20       Impact factor: 10.618

3.  Blood Coagulation Testing Smartphone Platform Using Quartz Crystal Microbalance Dissipation Method.

Authors:  Jia Yao; Bin Feng; Zhiqi Zhang; Chuanyu Li; Wei Zhang; Zhen Guo; Heming Zhao; Lianqun Zhou
Journal:  Sensors (Basel)       Date:  2018-09-13       Impact factor: 3.576

Review 4.  Technology Advancements in Blood Coagulation Measurements for Point-of-Care Diagnostic Testing.

Authors:  Mohammad Mohammadi Aria; Ahmet Erten; Ozlem Yalcin
Journal:  Front Bioeng Biotechnol       Date:  2019-12-11

5.  From a Laboratory Exercise for Students to a Pioneering Biosensing Technology.

Authors:  Ingemar Lundström
Journal:  Plasmonics       Date:  2014-01-16       Impact factor: 2.404

6.  Label-Free Oligonucleotide-Based SPR Biosensor for the Detection of the Gene Mutation Causing Prothrombin-Related Thrombophilia.

Authors:  Rodrigo Sierpe; Marcelo J Kogan; Soledad Bollo
Journal:  Sensors (Basel)       Date:  2020-10-31       Impact factor: 3.576

  6 in total