Literature DB >> 10638844

Spatial and temporal measurements of NO2 in an urban area using continuous mobile monitoring and passive samplers.

G Norris1, T Larson.   

Abstract

This paper describes the use of a continuous mobile monitor and passive samplers to estimate the spatial distribution of NO2 in an urban area for the purpose of siting a continuous monitor to measure population exposure. Monitoring sites were sites selected based on the State and Local Air Monitoring Stations (SLAMS) and National Air Monitoring Station (NAMS) siting criteria required by the U.S. Environmental Protection Agency (U.S. EPA). SLAMS monitoring objectives define scales in which the NO2 concentration and land use are homogeneous. The SLAMS scales relevant to NO2 monitoring for NAMS NO2 monitoring sites are neighborhood (0.5 to 4 km), and urban (several to 50 km). SLAMS siting objectives also define four categories of sites: highest concentration, representative concentration, impacts of major sources, and background sites. Mobile monitoring with a Scintrex LMA-3 luminal monitor was used on a neighborhood scale to measure the NO2 concentration at sites that covered a large geographical area. Passive samplers were then located at candidate mobile monitoring locations for long-term sampling which covered the neighborhood to the urban scale. These two methods complement each other by combining short-term continuous measurements and integrated long-term measurements which reflect the National Ambient Air Quality Standard for NO2 which is based on an annual average. The neighborhood site with the highest concentration was not only in the area of highest population density, but was also representative of the larger urban scale. The magnitude of this urban scale is approximately 20 km.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10638844     DOI: 10.1038/sj.jea.7500063

Source DB:  PubMed          Journal:  J Expo Anal Environ Epidemiol        ISSN: 1053-4245


  3 in total

1.  Evaluation of ogawa passive sampling devices as an alternative measurement method for the nitrogen dioxide annual standard in El Paso, Texas.

Authors:  Mark E Sather; E Terrence Slonecker; Johnson Mathew; Hunter Daughtrey; Dennis D Williams
Journal:  Environ Monit Assess       Date:  2006-10-03       Impact factor: 2.513

Review 2.  Passive dosimeters for nitrogen dioxide in personal/indoor air sampling: a review.

Authors:  Chang Ho Yu; Maria T Morandi; Clifford P Weisel
Journal:  J Expo Sci Environ Epidemiol       Date:  2008-04-30       Impact factor: 5.563

3.  Use of mobile and passive badge air monitoring data for NOX and ozone air pollution spatial exposure prediction models.

Authors:  Wei Xu; Erin A Riley; Elena Austin; Miyoko Sasakura; Lanae Schaal; Timothy R Gould; Kris Hartin; Christopher D Simpson; Paul D Sampson; Michael G Yost; Timothy V Larson; Guangli Xiu; Sverre Vedal
Journal:  J Expo Sci Environ Epidemiol       Date:  2016-03-23       Impact factor: 5.563

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.