Literature DB >> 10635187

Precision of CNC-milled titanium frameworks for implant treatment in the edentulous jaw.

T Jemt1, T Bäck, A Petersson.   

Abstract

PURPOSE: The purpose of this report was to describe a new technique to fabricate one-piece, implant-supported titanium frameworks by means of a computer numeric-controlled (CNC) milling technique, and to compare the fit of these frameworks with conventional cast prostheses.
MATERIALS AND METHODS: The study comprised 20 patients who were provided with 5 standard Brånemark implants each in the edentulous mandible. The fit of the first 10 prostheses with CNC-milled frameworks was measured by means of a 3-dimensional photogrammetric technique. The distortion of the center point of the framework cylinders was measured in relation to the master cast replicas. These measurements were compared with 10 randomly selected routine prostheses with cast frameworks.
RESULTS: No significant differences were found between the 2 groups. The 3-dimensional distortion of the cylinders in the completed prostheses ranged from 3 to 80 microns; no passive framework was observed. More distortion was observed in the horizontal plane (x and y axes) as compared to the distortion in the vertical direction (z axis).
CONCLUSION: The precision of fit of the first CNC-milled prostheses presented a comparable fit to the conventional cast frameworks. Consequently, this new technique could be a valid option for the routine fabrication of frameworks for implant prostheses.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10635187

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  9 in total

1.  Radiological evaluation of the Cresco system in combination with Osseospeed implants: a preliminary 3-year report.

Authors:  N Baldini; M DE Sanctis; M C Cagidiaco; P Balleri; F Vignoletti; C Goracci; M Ferrari
Journal:  Oral Implantol (Rome)       Date:  2014-12-27

2.  CAD/CAM technologies in the surgical and prosthetic treatment of the edentulous patient with biomymetic individualized approach.

Authors:  A Pozzi; M Gargari; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2008-06-16

3.  Retention strength between veneering resin composites and laser-sintered cobalt-chromium alloy.

Authors:  Kohji Kamada; Yohsuke Taira; Tadateru Sumi; Takashi Sawase
Journal:  Odontology       Date:  2016-06-20       Impact factor: 2.634

4.  Comparative study of the shear bond strength of various veneering materials on grade II commercially pure titanium.

Authors:  Eun-Young Lee; Sul-Gi Jun; Robert F Wright; Eun-Jin Park
Journal:  J Adv Prosthodont       Date:  2015-02-17       Impact factor: 1.904

5.  Full mouth rehabilitation with retrievable metal-ceramic implant-supported fixed prostheses for a young patient with atrophic jaws: a clinical report.

Authors:  Narges Ameri; Marzieh Alikhasi; Vida Rezayani
Journal:  Clin Case Rep       Date:  2017-08-10

6.  Dimensional Changes of 3-Unit Implant-Supported Zirconia Frameworks of Two CAD/CAM Systems from Scanning to Sintering.

Authors:  Marzieh Alikhasi; Narges Ameri; Hakimeh Siadat; Ahmad Reza Shamshiri; Mohammadreza Nejati
Journal:  Front Dent       Date:  2019-06-29

7.  A technique for in vitro fit assessment of multi-unit screw-retained implant restorations: Application of a triple-scan protocol.

Authors:  Stefan Holst; Matthias Karl; Manfred Wichmann; Ragai E Matta
Journal:  J Dent Biomech       Date:  2012-07-20

8.  Rationale for the use of CAD/CAM technology in implant prosthodontics.

Authors:  Jaafar Abduo; Karl Lyons
Journal:  Int J Dent       Date:  2013-04-16

Review 9.  Trends in computer-aided manufacturing in prosthodontics: a review of the available streams.

Authors:  Jaafar Abduo; Karl Lyons; Mohammed Bennamoun
Journal:  Int J Dent       Date:  2014-04-08
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.