Literature DB >> 10634182

Bone marrow processing for transplantation using the COBE spectra cell separator.

Z Korístek1, J Mayer.   

Abstract

BM processing, volume reduction, and granulocyte and erythrocyte depletion are important considerations for minimizing the side effects of graft administration and bypassing ABO incompatibility in allogeneic BMT. We used the COBE Spectra cell separator for BM processing in 33 patients suffering from hematologic malignancy and solid tumor (median age 39 years). We processed 42 BM harvests with the aim of maximizing recovery of mononuclear cells (MNC). BM was collected from the posterior iliac crest under general anesthesia. The mean volume of collected BM before filtration was 1,303 ml, and the mean number of collected total nucleated cells (TNC) was 2.61 x 10(8)/kg. The BM processing resulted in a mean recovery of 35.8% (10.1%-78.3%) TNC, 22.3% (1.1%-75.7%) of granulocytes, 78.8% (34.3%-135.2%) of MNC, 77.2% (8.3%-260.0%) of CD34+ cells, and 153.3% (32.9%-464.0%) of colony-forming units (CFU-GM) in the final product. A mean of 98.2% (94.5%-99.5%) of RBC was removed, with a mean of 13.3 ml (5.1-26.2 ml) of RBC in the final product. BM processing using the COBE Spectra cell separator proved to be fast, safe, and effective. However, the reasons for the very wide range of recovery of harvested CD34+ cells and CFU-GM need to be further investigated.

Entities:  

Mesh:

Year:  1999        PMID: 10634182     DOI: 10.1089/152581699320207

Source DB:  PubMed          Journal:  J Hematother Stem Cell Res        ISSN: 1525-8165


  3 in total

Review 1.  The processing of stem cell concentrates from the bone marrow in ABO-incompatible transplants: how and when.

Authors:  Nicola Daniele; Maria Cristina Scerpa; Cecilia Rossi; Alessandro Lanti; Gaspare Adorno; Giancarlo Isacchi; Francesco Zinno
Journal:  Blood Transfus       Date:  2013-11-21       Impact factor: 3.443

2.  RBC depletion from a PBSC graft.

Authors:  H Bonig; G Bug
Journal:  Bone Marrow Transplant       Date:  2017-04-24       Impact factor: 5.483

3.  Erythrocyte depletion from bone marrow: performance evaluation after 50 clinical-scale depletions with Spectra Optia BMC.

Authors:  Soo-Zin Kim-Wanner; Gesine Bug; Juliane Steinmann; Salem Ajib; Nadine Sorg; Carolin Poppe; Milica Bunos; Eva Wingenfeld; Christiane Hümmer; Beate Luxembourg; Erhard Seifried; Halvard Bonig
Journal:  J Transl Med       Date:  2017-08-11       Impact factor: 5.531

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.