Three-dimensional reconstruction of high contrast objects using C-arm image intensifier projection data.

M Grass1, R Koppe, E Klotz, R Proksa, M H Kuhn, H Aerts, J Op de Beek, R Kemkers.   

Abstract

The reconstruction of three-dimensional (3D) objects from 2D X-ray cone-beam projections using a circular source path is most commonly done with an algorithm according to Feldkamp et al. [Feldkamp LA, Davis LC, Kress JW. Practical cone-beam algorithms. J Opt Soc Am A 1984;6:612-619]. An adaptation of this so-called Feldkamp method to cone-beam projections acquired with a C-arm system is presented here. In a phantom study, reconstruction results obtained along real source-detector trajectories of a C-arm system are compared to reconstruction results obtained from projections acquired from a full-circular trajectory and from one consisting of two full orthogonal circles, which fulfills Tuy's sufficiency condition. The straightforward application of Feldkamp's method adapted to projection data obtained with a C-arm system illustrates the 3D imaging potential of image intensifier based cone-beam computed tomography. Reconstruction results from projection data of different patients acquired with a motorized C-arm system such as vessel structures filled with contrast agent and bones are presented.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10634143     DOI: 10.1016/s0895-6111(99)00028-2

Source DB:  PubMed          Journal:  Comput Med Imaging Graph        ISSN: 0895-6111            Impact factor:   4.790


  19 in total

1.  3D roadmap in neuroangiography: technique and clinical interest.

Authors:  Michael Söderman; D Babic; R Homan; T Andersson
Journal:  Neuroradiology       Date:  2005-07-07       Impact factor: 2.804

Review 2.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

Review 3.  C-arm flat detector computed tomography: the technique and its applications in interventional neuro-radiology.

Authors:  Mudassar Kamran; Sanjoy Nagaraja; James V Byrne
Journal:  Neuroradiology       Date:  2009-10-27       Impact factor: 2.804

Review 4.  Potential role of three-dimensional rotational angiography and C-arm CT for valvular repair and implantation.

Authors:  Jonathan G Schwartz; Anne M Neubauer; Thomas E Fagan; Niels J Noordhoek; Michael Grass; John D Carroll
Journal:  Int J Cardiovasc Imaging       Date:  2011-03-11       Impact factor: 2.357

Review 5.  The evolution of image-guided lumbosacral spine surgery.

Authors:  Austin C Bourgeois; Austin R Faulkner; Alexander S Pasciak; Yong C Bradley
Journal:  Ann Transl Med       Date:  2015-04

6.  Discriminative generalized Hough transform for object localization in medical images.

Authors:  Heike Ruppertshofen; Cristian Lorenz; Georg Rose; Hauke Schramm
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-02-09       Impact factor: 2.924

7.  Automatic bone removal for 3D TACE planning with C-arm CBCT: Evaluation of technical feasibility.

Authors:  Zhijun Wang; Eberhard Hansis; Rongxin Chen; Rafael Duran; Julius Chapiro; Yun Robert Sheu; Hicham Kobeiter; Michael Grass; Jean-François Geschwind; MingDe Lin
Journal:  Minim Invasive Ther Allied Technol       Date:  2016-02-29       Impact factor: 2.442

Review 8.  How I do it: Cone-beam CT during transarterial chemoembolization for liver cancer.

Authors:  Vania Tacher; Alessandro Radaelli; MingDe Lin; Jean-François Geschwind
Journal:  Radiology       Date:  2015-02       Impact factor: 11.105

9.  Accurate image reconstruction using real C-arm data from a Circle-plus-arc trajectory.

Authors:  Stefan Hoppe; Joachim Hornegger; Frank Dennerlein; Günter Lauritsch; Frédéric Noo
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-05-21       Impact factor: 2.924

10.  Brain imaging with a flat detector C-arm : Technique and clinical interest of XperCT.

Authors:  M Söderman; D Babic; S Holmin; T Andersson
Journal:  Neuroradiology       Date:  2008-06-17       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.