Evaluation of the effectiveness of transurethral radio frequency hyperthermia in the canine prostate: temperature distribution analysis.

L Zhu1, L X Xu.   

Abstract

The heating pattern of a transurethral radio frequency (RF) applicator and its induced steady-state temperature field in the prostate during transurethral hyperthermia treatment were investigated in this study. The specific absorption rate (SAR) of the electromagnetic energy was first quantified in a tissue-equivalent gel phantom. It was used in conjunction with the Pennes bioheat transfer equation to model the steady-state temperature field in prostate during the treatment. Theoretical predictions were compared to in vivo temperature measurements in the canine prostate and good agreement was found to validate the model. The prostatic tissue temperature rise and its relation to the effect of blood perfusion were analyzed. Blood perfusion is found to be an important factor for removal of heat especially at the higher RF heating level. To achieve a temperature above 44 degrees C within 10 percent of the prostatic tissue volume, the minimum RF power required ranges from 5.5 W to 36.4 W depending on the local blood perfusion rate (omega = 0.2-1.5 ml/gm/min). The corresponding histological results from the treatment suggest that to obtain better treatment results, either higher RF power level or longer treatment time (> 180 minutes) is necessary. This is consistent with the predictions from the theoretical model developed in this study.

Entities:  

Mesh:

Year:  1999        PMID: 10633257     DOI: 10.1115/1.2800857

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  4 in total

1.  Effects of variation in perfusion rates and of perfusion models in computational models of radio frequency tumor ablation.

Authors:  David J Schutt; Dieter Haemmerich
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

2.  Theoretical simulation of temperature distribution in the brain during mild hypothermia treatment for brain injury.

Authors:  L Zhu; C Diao
Journal:  Med Biol Eng Comput       Date:  2001-11       Impact factor: 3.079

3.  A new radiofrequency balloon angioplasty device for atherosclerosis treatment.

Authors:  Shiqing Zhao; Jincheng Zou; Hongying Wang; Jinbao Qin; Xinwu Lu; Aili Zhang; Lisa X Xu
Journal:  Biomed Eng Online       Date:  2020-06-10       Impact factor: 2.819

4.  Thermal modeling of lesion growth with radiofrequency ablation devices.

Authors:  Isaac A Chang; Uyen D Nguyen
Journal:  Biomed Eng Online       Date:  2004-08-06       Impact factor: 2.819

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.