Abstract

Aseptic loosening is thought to be due primarily to osteolysis induced by cytokines and prostaglandins that are produced in response to implant-derived wear particles. Because endotoxin has many of the same effects as have been reported for wear particles, we hypothesized that adherent endotoxin may be responsible for the biological responses induced by wear particles. We demonstrated the presence of significant levels of adherent endotoxin on commonly used preparations of titanium particles as well as on titanium and titanium-alloy implant surfaces. In contrast, supernatants obtained by centrifugation of particle suspensions contained approximately 1% as much endotoxin as did the particles. Therefore, it is erroneous to assume that particles do not contain endotoxin on the basis of data that it cannot be detected in their supernatants or filtrates. These results emphasize the importance of considering the potential role of adherent endotoxin when examining the in vitro effects of wear particles and the in vivo performance of orthopaedic implants. We also developed a protocol that removed more than 99.94% of the adherent endotoxin from the titanium particles without detectably affecting their size or shape. The removal of adherent endotoxin will allow comparison of the biological responses induced by particles with or without adherent endotoxin.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10632445     DOI: 10.1002/jor.1100170603

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  41 in total

1.  Inhibitory effect of (-)-epigallocatechin gallate on titanium particle-induced TNF-α release and in vivo osteolysis.

Authors:  Shan Jin; Ju Young Park; Jung Min Hong; Tae Ho Kim; Hong In Shin; Eui Kyun Park; Shin Yoon Kim
Journal:  Exp Mol Med       Date:  2011-07-30       Impact factor: 8.718

2.  The effect of particle size and electrical charge on macrophage-osteoclast differentiation and bone resorption.

Authors:  A Sabokbar; R Pandey; N A Athanasou
Journal:  J Mater Sci Mater Med       Date:  2003-09       Impact factor: 3.896

3.  Comparison of the cytotoxic and inflammatory responses of titanium particles with different methods for endotoxin removal in RAW264.7 macrophages.

Authors:  Huifeng Ding; Zhenan Zhu; Tingting Tang; Degang Yu; Bo Yu; Kerong Dai
Journal:  J Mater Sci Mater Med       Date:  2012-02-23       Impact factor: 3.896

4.  Bacterial pathogen-associated molecular patterns stimulate biological activity of orthopaedic wear particles by activating cognate Toll-like receptors.

Authors:  Edward M Greenfield; Michelle A Beidelschies; Joscelyn M Tatro; Victor M Goldberg; Amy G Hise
Journal:  J Biol Chem       Date:  2010-08-19       Impact factor: 5.157

5.  Bone turnover markers correlate with implant fixation in a rat model using LPS-doped particles to induced implant loosening.

Authors:  Shuo Liu; Amarjit S Virdi; Kotaro Sena; W Frank Hughes; Dale R Sumner
Journal:  J Biomed Mater Res A       Date:  2012-01-24       Impact factor: 4.396

6.  Removing Endotoxin from Metallic Biomaterials with Compressed Carbon Dioxide-Based Mixtures.

Authors:  Pedro J Tarafa; Eve Williams; Samir Panvelker; Jian Zhang; Michael A Matthews
Journal:  J Supercrit Fluids       Date:  2011-01-01       Impact factor: 4.577

Review 7.  Unintended effects of drug carriers: Big issues of small particles.

Authors:  Hamideh Parhiz; Makan Khoshnejad; Jacob W Myerson; Elizabeth Hood; Priyal N Patel; Jacob S Brenner; Vladimir R Muzykantov
Journal:  Adv Drug Deliv Rev       Date:  2018-07-03       Impact factor: 15.470

8.  Adherent lipopolysaccharide inhibits the osseointegration of orthopedic implants by impairing osteoblast differentiation.

Authors:  Lindsay A Bonsignore; J Robert Anderson; Zhenghong Lee; Victor M Goldberg; Edward M Greenfield
Journal:  Bone       Date:  2012-09-17       Impact factor: 4.398

9.  Aggravation of inflammatory response by costimulation with titanium particles and mechanical perturbations in osteoblast- and macrophage-like cells.

Authors:  Heon Goo Lee; Anny Hsu; Hana Goto; Saqib Nizami; Jonathan H Lee; Edwin R Cadet; Peter Tang; Roya Shaji; Chandhanarat Chandhanayinyong; Seok Hyun Kweon; Daniel S Oh; Hesham Tawfeek; Francis Y Lee
Journal:  Am J Physiol Cell Physiol       Date:  2012-12-19       Impact factor: 4.249

10.  Integrin-directed modulation of macrophage responses to biomaterials.

Authors:  Toral D Zaveri; Jamal S Lewis; Natalia V Dolgova; Michael J Clare-Salzler; Benjamin G Keselowsky
Journal:  Biomaterials       Date:  2014-01-24       Impact factor: 12.479

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.