Literature DB >> 10630802

Hinged external fixation of the elbow: optimal axis alignment to minimize motion resistance.

S M Madey1, M Bottlang, C M Steyers, J L Marsh, T D Brown.   

Abstract

OBJECTIVE: To establish an optimal single hinge axis position for application of hinged external fixation to the elbow joint.
DESIGN: Cadaveric biomechanical investigation.
SETTING: A customized motion transducer applied passive elbow motion to six cadaveric upper extremities. The instant rotation axis of the humero-ulnar articulation was determined from three-dimensional kinematic data acquired by an electromagnetic motion tracking system. For each specimen, an optimal fixator hinge position was calculated from these motion data. INTERVENTION: A prototype articulated external fixator was applied to the elbow, first with its hinge aligned along the computed optimal position. Then the fixator was mounted in sixteen distinct off-axis positions. MAIN OUTCOME MEASURE: Additional resistance to joint motion (in terms of energy) corresponding to deliberately introduced amounts of relative malalignment between the optimal elbow axis and the actual fixator hinge axis.
RESULTS: Aligning the fixator hinge along the optimized axis position resulted in a minimal amount of energy (0.15 joules) needed to rotate the elbow through a prescribed range of motion. Malpositioning the hinge by ten millimeters caused up to ten times that amount of motion resistance.
CONCLUSIONS: An optimal fixator hinge position can be determined to minimize the increase in motion resistance due to fixator application. The severely increased motion resistance associated with small amounts of malalignment between the fixator hinge and the anatomic elbow axis suggests the need for highly accurate fixator hinge application.

Mesh:

Year:  2000        PMID: 10630802     DOI: 10.1097/00005131-200001000-00009

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  12 in total

1.  A new articulated elbow external fixation technique for difficult elbow trauma.

Authors:  F von Knoch; J L Marsh; C Steyers; T McKinley; M O'Rourke; M Bottlang
Journal:  Iowa Orthop J       Date:  2001

2.  [Complex osteoligamentary injuries of the elbow. Treatment with a hinged external fixator].

Authors:  W Kolb; H Guhlmann; C Windisch; F Marx; E Markgraf; H Koller; K Kolb; P Grützner
Journal:  Unfallchirurg       Date:  2008-08       Impact factor: 1.000

3.  Vortical flow in human elbow joints: a three-dimensional computed tomography modeling study.

Authors:  Arnold Adikrishna; Aashay L Kekatpure; Jun Tan; Hyun-Joo Lee; Maria Florencia Deslivia; In-Ho Jeon
Journal:  J Anat       Date:  2014-08-05       Impact factor: 2.610

4.  Cadaveric assessment of a 3D-printed aiming device for implantation of a hinged elbow external fixator.

Authors:  Alexandre Dos Santos; Maud Creze; Matthieu Begin; Elisabeth Laemmel; Bouchra Assabah; Marc Soubeyrand
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-12-10

5.  [A hinged external fixator for treatment of complex elbow joint injuries].

Authors:  T Schmickal; D Hoentzsch; A Wentzensen
Journal:  Unfallchirurg       Date:  2007-04       Impact factor: 1.000

6.  An X-ray-free method to accurately identify the elbow flexion-extension axis for the placement of a hinged external fixator.

Authors:  Jian Song; Hui Ding; Wei Han; Junqiang Wang; Guangzhi Wang
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-11-03       Impact factor: 2.924

7.  Combined use of minimal screw synthesis and external articulated fixation is effective for the management of supra-intercondyloid humeral fractures in the elderly? A retrospective study.

Authors:  Fabrizio Bienati; Alessandro Isola; Sebastiano Ortu; Luca Bonini; Rossella Sirianni; Antonio Capone; Mario Manca
Journal:  J Orthop       Date:  2022-09-27

8.  Additional external hinged fixator after open repositioning and internal fixation of acute elbow instability in non-compliant patients.

Authors:  Sebastian Berendes; Christoph Zilkens; Alexandros Anastasiadis; Markus Graf; Gert Muhr; Thomas Kalicke
Journal:  Orthop Rev (Pavia)       Date:  2010-09-23

9.  Hinged external fixation for Regan-Morrey type I and II fractures and fracture-dislocations.

Authors:  Alberto Castelli; Salvatore D'amico; Alberto Combi; Francesco Benazzo
Journal:  J Orthop Traumatol       Date:  2016-02-13

10.  [Mid-term effectiveness of arthrolysis and hinged external fixation for treatment of stiff elbow caused by heterotrophic ossification].

Authors:  Xiaolong Zheng; Mingyu Yang; Miduo Mu; Xia Kang; Aining Yang; Binghua Zhou; Kanglai Tang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2019-10-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.