Literature DB >> 10626770

DNA sequencing using 96-capillary array electrophoresis.

H Pang1, V Pavski, E S Yeung.   

Abstract

Practical DNA sequencing in a rugged capillary array electrophoresis system coupled directly to 96-well microtiter plates is demonstrated. A CCD detector was used to monitor all capillaries simultaneously with laser-induced fluorescence at 1.75 frames per second. The reconstructed electropherograms show good signal-to-noise ratios and resolution for the entire capillary array. The system used standard dye labeling and image splitting to obtain fluorescence intensities in two wavelength regions to allow calling up to 410 bases for the DNA sequence. The use of a replaceable poly(ethylene oxide) matrix and a protective poly(vinylpyrrolidone) coating allows high separation speed and short turnaround time for high throughput DNA sequencing. Critical evaluation of the system performance over repeated runs with base calling is presented.

Entities:  

Mesh:

Year:  1999        PMID: 10626770     DOI: 10.1016/s0165-022x(99)00042-1

Source DB:  PubMed          Journal:  J Biochem Biophys Methods        ISSN: 0165-022X


  6 in total

1.  Automated one-step DNA sequencing based on nanoliter reaction volumes and capillary electrophoresis.

Authors:  H M Pang; E S Yeung
Journal:  Nucleic Acids Res       Date:  2000-08-01       Impact factor: 16.971

2.  Thermoplastic microfluidic devices and their applications in protein and DNA analysis.

Authors:  Ke Liu; Z Hugh Fan
Journal:  Analyst       Date:  2011-01-28       Impact factor: 4.616

3.  Coaxial flow system for chemical cytometry.

Authors:  Paul J Marc; Christopher E Sims; Nancy L Allbritton
Journal:  Anal Chem       Date:  2007-11-03       Impact factor: 6.986

4.  Shotgun optical maps of the whole Escherichia coli O157:H7 genome.

Authors:  A Lim; E T Dimalanta; K D Potamousis; G Yen; J Apodoca; C Tao; J Lin; R Qi; J Skiadas; A Ramanathan; N T Perna; G Plunkett; V Burland; B Mau; J Hackett; F R Blattner; T S Anantharaman; B Mishra; D C Schwartz
Journal:  Genome Res       Date:  2001-09       Impact factor: 9.043

5.  Current awareness.

Authors:  R Drysdale; L Bayraktaroglu
Journal:  Yeast       Date:  2000-06-30       Impact factor: 3.239

6.  Comparison of the mismatch-specific endonuclease method and denaturing high-performance liquid chromatography for the identification of HBB gene mutations.

Authors:  Chia-Cheng Hung; Yi-Ning Su; Chia-Yun Lin; Yin-Fei Chang; Chien-Hui Chang; Wen-Fang Cheng; Chi-An Chen; Chien-Nan Lee; Win-Li Lin
Journal:  BMC Biotechnol       Date:  2008-08-12       Impact factor: 2.563

  6 in total