Literature DB >> 10624975

The effect of transesophageal echocardiography on ventilation in small infants undergoing cardiac surgery.

D B Andropoulos1, N A Ayres, S A Stayer, S T Bent, C J Campos, C D Fraser.   

Abstract

UNLABELLED: Transesophageal echocardiography (TEE) is frequently used during congenital cardiac surgery. Complications are infrequent, but interference with ventilation has been reported, especially in small infants. Ventilation variables were measured prospectively in 22 infants, 2-5 kg, undergoing heart surgery with TEE. Measurements were made preoperatively before and after TEE probe insertion and postoperatively before and after TEE probe removal. The variables measured included arterial blood gases, expired tidal volume, peak inspiratory pressure, positive end-expiratory pressure, minute ventilation, airway resistance, dynamic compliance, and peak inspiratory and expiratory flow rates. No significant change in any ventilatory variable at either time period was noted in the infants. IMPLICATIONS: Ventilatory compromise is infrequent in small infants undergoing transesophageal echocardiography (TEE) examination. Careful ventilatory monitoring rapidly detects changes in ventilation during TEE examination. Small infants who benefit from TEE during heart surgery should not be excluded from receiving a TEE examination because of concern of ventilatory compromise.

Entities:  

Mesh:

Year:  2000        PMID: 10624975     DOI: 10.1097/00000539-200001000-00011

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  4 in total

Review 1.  Trans-oesophageal echocardiography (TOE): contra-indications, complications and safety of perioperative TOE.

Authors:  Neil David Hauser; Justiaan Swanevelder
Journal:  Echo Res Pract       Date:  2018-08-11

Review 2.  Anesthesia and postoperative analgesia in pediatric patients undergoing cardiac surgery.

Authors:  Laura K Diaz
Journal:  Paediatr Drugs       Date:  2006       Impact factor: 3.022

3.  Intravascular ultrasound catheter for transesophageal echocardiography in congenital heart surgery -A case report-.

Authors:  Hye-Jin Kim; Jae-Yun Kim; Seung-Hoon Baek; Hae-Kyu Kim
Journal:  Korean J Anesthesiol       Date:  2010-05-31

4.  Transoesophageal echocardiography (TOE): contra-indications, complications and safety of perioperative TOE

Authors:  Neil David Hauser; Justiaan Swanevelder
Journal:  Echo Res Pract       Date:  2018-12-01
  4 in total